Background: The changes of hemodynamics caused by the implantation of multilayer stent (MS) have significant effects for aneurysm sac.

Methods: Comparisons of 3D numerical models with/without a MS in an abdominal aortic aneurysm with a 90° branch vessel were numerically studied from the viewpoint of hemodynamics.

Results: The results showed that: (1) The flow fields and Wall Shear Stress (WSS) are changed dramatically after MS implantation. The velocity of the blood flow in aneurysm sac decreases significantly and the regions of low-WSS increase. These help thrombus formation; (2) The pressure in aneurysm slightly decreases and keeps close to the normal level of blood pressure, however the risk of aneurysm enlargement or even rupture still exists; (3) The flux and the velocity in branch artery are reduced by about half after MS implantation. Due to the implantation of MS, the changes in the flow field causes the decrease of pressure/WSS in aneurysm sac and the blood flow in branch vessel.

Conclusions: The implantation of MS into abdominal artery results in more low-WSS regions inside aneurysm which induces thrombus formation. The pressure is reduced slightly means the risk of aneurysm rupture exists.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5260060PMC
http://dx.doi.org/10.1186/s12938-016-0248-0DOI Listing

Publication Analysis

Top Keywords

multilayer stent
8
aneurysm
8
blood flow
8
aneurysm sac
8
thrombus formation
8
formation pressure
8
risk aneurysm
8
rupture exists
8
implantation
5
hemodynamics study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!