Compliance with Gastric-Emptying Scintigraphy Guidelines: An Analysis of the Intersocietal Accreditation Commission Database.

J Nucl Med Technol

Nuclear Medicine Service, Department of Veterans Affairs Ann Arbor Healthcare System, Ann Arbor. Michigan.

Published: March 2017

Many variables can influence the results of gastric emptying scintigraphy (GES). A lack of methodologic standardization may cause variability, limit comparisons, and decrease the credibility of the test. To address this, in 2009, the Society of Nuclear Medicine and Molecular Imaging (SNMMI) published a procedure guideline describing a standardized, validated GES protocol for adults. Laboratories must closely follow the consensus protocol to provide valid and standardized results and improve patient care. The Intersocietal Accreditation Commission (IAC) evaluates compliance with guidelines as part of the accreditation process. The rate of compliance with the GES guideline at a national level has not been assessed. The aim of this study was to quantify compliance with the standardized protocol in a large cohort of laboratories from different institutions and practice settings across the United States. The IAC Nuclear/PET database was used to extract GES protocols from all laboratories applying for accreditation from 2013 to 2015. Each protocol was assessed for compliance with the methods described in the SNMMI GES procedure guidelines. Fourteen binary variables were assessed: patient preparation (4 variables), meal content (5 variables), acquisition (2 variables), and processing (3 variables). Protocols from 127 labs demonstrated that patient preparation was the category with which the laboratories were least compliant. Instructions for blood glucose monitoring and withholding of medications were problematic. Overall, 69.3% of protocols were not compliant with the content or preparation of the consensus meal: 47.3% used whole eggs instead of egg whites, and additional ingredients not recommended in the guidelines were also frequently used. Only 3.1% of laboratories were fully compliant with all 14 variables. Over half the laboratories were compliant with only 5 variables or less. Almost 8 y after the publication of the SNMMI GES guidelines, there is low protocol adherence among laboratories applying for IAC Nuclear/PET accreditation. This substantial degree of guideline noncompliance is concerning. The variability in GES protocols may have a significant effect on patient management, as results may be inaccurate. Consistent use of the standardized GES protocol permits interpretation of results in a standardized manner that allows interlaboratory comparisons and fosters acceptance of the test validity by referring clinicians.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnmt.116.184473DOI Listing

Publication Analysis

Top Keywords

intersocietal accreditation
8
accreditation commission
8
variables
8
ges
8
ges protocol
8
iac nuclear/pet
8
ges protocols
8
laboratories applying
8
snmmi ges
8
patient preparation
8

Similar Publications

Carotid Ultrasound.

Radiol Clin North Am

January 2025

Department of Radiological Sciences, David Geffen School of Medicine at UCLA, USC Keck School of Medicine, Los Angeles, CA, USA; Department of Radiology, Greater Los Angeles VA Medical Center, 11301 Wilshire Boulevard, Los Angeles, CA 90073, USA.

Carotid ultrasound is the primary noninvasive method for detecting, grading, and monitoring internal carotid artery (ICA) stenosis. Major components of carotid Doppler ultrasound include assessment of ICA stenosis using Doppler velocity criteria, spectral waveform analysis, and assessment of ICA stenosis. Recently, the Intersocietal Accreditation Commission Vascular Testing put forth new modified Society of Radiologists in Ultrasound criteria with a higher peak systolic velocity threshold of 180 cm/s for 50% to 69% ICA stenosis.

View Article and Find Full Text PDF

Combined Supine-Prone Myocardial Perfusion Imaging: Enhancing Diagnostic Accuracy.

J Nucl Med Technol

December 2024

Intersocietal Accreditation Commission, Ellicott City, Maryland

The combined supine-prone imaging protocol for SPECT myocardial perfusion imaging offers significant advantages over supine imaging alone. By comparing supine and prone images, one can distinguish attenuation artifacts in the inferior and anterior walls from true perfusion defects, thus improving specificity and diagnostic accuracy. The recommended protocol is to perform prone imaging after supine stress imaging when perfusion defects are noted.

View Article and Find Full Text PDF

Objective: We compared the effectiveness and safety of polidocanol 1% endovenous microfoam ablation vs endovenous thermal ablation with radiofrequency or laser energy for treatment of venous insufficiency caused by lower extremity truncal vein incompetence via network meta-analysis of published comparative evidence.

Methods: We conducted a systematic literature review following best practices, including a prospective protocol. We screened studies published in English from 2000 to 2023 for randomized and nonrandomized studies reporting direct or indirect comparisons between polidocanol 1% endovenous microfoam and endovenous thermal ablation.

View Article and Find Full Text PDF

Gastric Emptying Solid-Meal Content and Misinformation on Social Media Platforms.

J Nucl Med Technol

March 2024

Intersocietal Accreditation Commission, Ellicott City, Maryland

Several nuclear medicine technologist-specific groups exist on social media sites such as Facebook and LinkedIn. Although these sites provide a valuable resource and forum for technologists to interact and pose questions, any recommendations, especially those regarding patient care, should be carefully scrutinized and evaluated on the basis of scientific merit and not opinion. Recently, an assortment of unvalidated ingredients for solid-meal gastric emptying scintigraphy has been suggested on these social media sites.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!