Background: Physical inactivity is an important modifiable risk factor for chronic diseases. A new wrist-worn heart rate and activity monitor has been developed for unobtrusive data collection to aid prevention and management of lifestyle-related chronic diseases by means of behavioral change programs.

Objective: The objective of the study was to evaluate the performance of total energy expenditure and resting heart rate measures of the Philips health watch. Secondary objectives included the assessment of accuracy of other output parameters of the monitor: heart rate, respiration rate at rest, step count, and activity type recognition.

Methods: A within-person comparative study was performed to assess the performance of the health watch against (medical) reference measures. Participants executed a protocol including 15 minutes of rest and various activities of daily life. A two one-sided tests approach was adopted for testing equivalence. In addition, error metrics such as mean error and mean absolute percentage error (MAPE) were calculated.

Results: A total of 29 participants (14 males; mean age 41.2, SD 14.4, years; mean weight 77.2, SD 10.2, kg; mean height 1.8, SD 0.1, m; mean body mass index 25.1, SD 3.1, kg/m) completed the 81-minute protocol. Their mean resting heart rate in beats per minute (bpm) was 64 (SD 7.3). With a mean error of -10 (SD 38.9) kcal and a MAPE of 10% (SD 8.7%), total energy expenditure estimation of the health watch was found to be within the 15% predefined equivalence margin in reference to a portable indirect calorimeter. Resting heart rate determined during a 15-minute rest protocol was found to be within a 10% equivalence margin in reference to a wearable electrocardiogram (ECG) monitor, with a mean deviation of 0 bpm and a maximum deviation of 3 bpm. Heart rate was within 10 bpm and 10% of the ECG monitor reference for 93% of the duration of the protocol. Step count estimates were on average 21 counts lower than a waist-mounted step counter over all walking activities combined, with a MAPE of 3.5% (SD 2.4%). Resting respiration rate was on average 0.7 (SD 1.1) breaths per minute lower than the reference measurement by the spirometer embedded in the indirect calorimeter during the 15-minute rest, resulting in a MAPE of 8.3% (SD 7.0%). Activity type recognition of walking, running, cycling, or other was overall 90% accurate in reference to the activities performed.

Conclusions: The health watch can serve its medical purpose of measuring resting heart rate and total energy expenditure over time in an unobtrusive manner, thereby providing valuable data for the prevention and management of lifestyle-related chronic diseases.

Trial Registration: Netherlands trial register NTR5552; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=5552 (Archived by WebCite at http://www.webcitation.org/6neYJgysl).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5314101PMC
http://dx.doi.org/10.2196/mhealth.6893DOI Listing

Publication Analysis

Top Keywords

heart rate
28
health watch
20
resting heart
16
total energy
12
energy expenditure
12
rate
9
philips health
8
within-person comparative
8
comparative study
8
chronic diseases
8

Similar Publications

Cardiovascular problems in rabbits in reference to hypothyroidism - a four-year retrospective study.

Pol J Vet Sci

December 2024

Department of Epizootiology and the Clinic of Infectious Diseases, Faculty of Veterinary Medicine, University of Life Sciences in Lublin, Głęboka 30, 20-612 Lublin, Poland.

The effects of T4 are mainly manifested by positive ino- and chronotropism. The syndrome accompanying hypothyroidism in rabbits (impaired myocardial contractility and reduced ejection capacity) is caused by a deficiency of thyroid hormones - especially T4. The study group consisted of a total of 41 animals: 15 males and 26 females, ranging in age from 2 months to 8 years, with echocardiogram showing reduced fractional shortening (<30%), with normal results of heamatological and biochemical tests.

View Article and Find Full Text PDF

Background: Cardiac computed tomography imaging with contrast is being used increasingly to image left atrial appendage occlusion (LAAO) devices. Contrast flow across a device, also known as a transfabric leak (TFL), may indicate a lack of complete LAAO-device endothelialization. The data on the rate, predictors, and clinical events associated with TFL are limited.

View Article and Find Full Text PDF

Background: Stroke is a feared complication after TAVI. The objective was to assess whether left atrial appendage (LAA) filling-defect (FD) patterns from early and late-phase computed tomography (CT), predict stroke/TIA in patients with severe aortic stenosis.

Methods: 124 patients with severe aortic stenosis (79.

View Article and Find Full Text PDF

Introduction: Adrenergic activation of protein kinase A (PKA) in cardiac muscle targets the sarcolemma, sarcoplasmic reticulum, and contractile apparatus to increase contractile force and heart rate. In the thin filaments of the contractile apparatus, cardiac troponin I (cTnI) Ser22 and Ser23 in the cardiac-specific N-terminal peptide (NcTnI: residues 1 to 32) are the targets for PKA phosphorylation. Phosphorylation causes a 2-3 fold decrease of affinity of cTn for Ca associated with a higher rate of Ca dissociation from cTnC leading to a faster relaxation rate of the cardiac muscle (lusitropy).

View Article and Find Full Text PDF

Background: Heart failure (HF) is a life-threatening condition with a high mortality rate. The precise relationship between the heart rate and temperature (HR/T) ratio and mortality in patients with HF remains unclear. This study aimed to investigate the relationship between the HR/T ratio and 28-day intensive care unit (ICU) mortality rates in patients with HF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!