The Effect of Fixation Technique on Continuous Interscalene Nerve Block Catheter Success: A Randomized, Double-Blind Trial.

Anesth Analg

From the *Department of Anesthesiology, Virginia Mason Medical Center, Seattle, Washington; and †Duke University School of Medicine, Department of Biostatistics and Bioinformatics, Durham, North Carolina.

Published: March 2017

Background: Continuous peripheral nerve blocks offer advantages over single-injection blocks, including extended analgesia and reduction in opioid consumption. These benefits require that the perineural catheter remain intact for the duration of the planned local anesthetic infusion. Mechanical displacement of catheters, leaking, and consequent failure are known complications. The aim of this study was to evaluate continuous perineural catheter tip-to-nerve apposition in vivo over 48 hours comparing 2 different simple fixation strategies.

Methods: Subjects presenting for a continuous interscalene nerve block were randomized to perineural catheter fixation with 1 of 2 types of adhesive: Dermabond (2-octylcyanoacrylate) or Mastisol (alcohol 23A, gum mastic, storax, and methyl salicylate), covered with a simple transparent dressing. The primary outcome was the evaluation of catheter-to-nerve apposition maintenance over 48 hours via both a blinded ultrasound evaluation of local anesthetic distribution and a blinded clinical assessment. Secondary outcomes included leakage at the catheter site, pain scores, opioid consumption, catheter-to-skin migration at the insertion site, and patient satisfaction.

Results: Sixty-six subjects were recruited and randomized to compare adhesive group catheter tip-to-nerve apposition on postoperative day 2 (POD 2). Within the intention-to-treat cohort, a statistically significant decrease of perineural catheter tip-to-nerve apposition in the Mastisol group (64.7%) compared with the Dermabond group (90.6%) on POD 2 (odds ratios [OR] 0.19; 95% confidence interval [CI] 0.05-0.75; P = .012) was observed. Similar results were observed on POD 1 (OR 0.19; 95% CI 0.03-1.38; P = NS) and POD 2 (OR 0.14; 95% CI 0.02-0.97; P = .008) within the as-treated cohort. Catheter leakage (OR 67; 95% CI 7.3-589) and median catheter migration difference at the skin insertion site (2.0 cm; 95% CI 0.5-2.5) were also significantly greater in the Mastisol group than in the Dermabond group from POD 0 to POD 2 (P < .001). Median postoperative opioid consumption difference in morphine equivalents (3.2 mg; 95% CI - 9.0 to 14.2) was not significantly different between the Dermabond and the Mastisol groups through POD 2 (P = .542).

Conclusions: Perineural catheter fixation with Dermabond in continuous interscalene nerve block improves maintenance of catheter-to-nerve apposition when compared with Mastisol.

Download full-text PDF

Source
http://dx.doi.org/10.1213/ANE.0000000000001811DOI Listing

Publication Analysis

Top Keywords

perineural catheter
20
continuous interscalene
12
interscalene nerve
12
nerve block
12
opioid consumption
12
catheter tip-to-nerve
12
tip-to-nerve apposition
12
catheter
10
local anesthetic
8
catheter fixation
8

Similar Publications

Lumbar epidural anesthesia is widely used for labor epidural analgesia (LEA), but it often results in insufficient analgesia in the sacral region. We report a case where we performed LEA using lumbar epidural anesthesia, and an asymptomatic sacral perineural cyst was considered the potential cause of inadequate analgesia in the sacral region. A 33-year-old primigravida was admitted with premature rupture of membranes.

View Article and Find Full Text PDF

Backround/objectives: We investigated a technique that facilitates the coiling of a regular straight catheter (with integral stylet) behind the sciatic nerve in an ultrasound (US) regional anaesthesia simulator, and then applied our findings to a series of orthopedic-trauma patients.

Methods: We conducted a randomized study of two methods of perineural catheter advancement in a sciatic nerve block Blue Phantom simulator. Two groups of twenty catheters each (method A and method B) were evaluated under real-time ultrasound imaging.

View Article and Find Full Text PDF

Background: There is scarce literature regarding the use of continuous peripheral nerve blocks in acute burn patients, who may be at higher risk for catheter-related complications, including infection. We sought to describe our center's experience and infection rate with continuous perineural catheters in the setting of pain management for patients suffering from burns.

Methods: A retrospective observational study was performed including all patients admitted to an American Burn Association-verified regional burn center between January 2018 and July 2023 who received a continuous peripheral nerve block for an acute burn injury.

View Article and Find Full Text PDF

Postmortem histology and in vivo, animal-based ultra-high-definition microultrasound demonstrate a complex array of non-communicating adipose tissue compartments enclosed by fascia. Classic nerve block mechanisms and histology do not consider this tissue. Injected local anesthetic agents can occupy any of these adipose compartments, which may explain the significant differences in outcomes such as success rates, onset time, block density, duration of nerve block, and secondary continuous block failure.

View Article and Find Full Text PDF

Background: Interscalene catheters (ISC) are considered as the gold standard for perioperative pain control after total shoulder arthroplasty. Liposomal bupivacaine (LB) for interscalene blocks (ISBs) and the addition of dexamethasone to ISBs have both presented as additional options for extended analgesia. We aimed to compare the efficacy of LB to a single-shot ISB (SISB) with added dexamethasone to an ISC.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!