Aim: To simulate and compare accommodation in accommodative and non-accommodative human eye models.
Methods: Ray tracing and optical design program was used. Three eye models were designed and studied: the Navarro, the Arizona and the Liou-Brennan. In order to make the Navarro and Liou-Brennan models to accommodate, specific geometric parameters of the models were altered with values that were chosen from the literature. For the Arizona model, its' mathematical functions for accommodation were used for the same accommodative demands. The simulation included four distances of accommodation for each model: at infinity, 3, 1 and 0.5 m.The results were diffraction images of a "letter F" for graphical comparison, spot diagrams on the retinal field and Modulation Transfer Function (MTF) graphs.
Results: Zernike coefficients for the aberrations, Airy disk diameter, root mean square (RMS) error diameter and total axial length of the model were provided from the program. These were compared between them in all distances. The Navarro model had the smallest axial length change as a simple model. The Arizona did not change its axial length because it is designed to be accommodative. The Liou-Brennan model had different results concerning the aberrations because of the decentration of the pupil. The MTF graphs showed small differences between the models because of the differences in their designs.
Conclusion: All the three models are able to simulate accommodation with the expected results. There is no model that can be assumed as the best choice. Accommodation can be simulated in non-accommodativemodels and in customized ones.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5225347 | PMC |
http://dx.doi.org/10.18240/ijo.2017.01.07 | DOI Listing |
J Ophthalmol
January 2025
Optics and Optometry Department, Universidad Complutense de Madrid, Madrid, Spain.
To analyze the refractive accuracy of a novel swept-source optical coherence biometer (SS-OCT), that uses individual refractive indices to measure axial length, in short and long eyes implanted with monofocal intraocular lenses (IOLs). This retrospective comparative study considered eyes with short axial length (AL) (< 22.5 mm) or long AL (> 26 mm) bilaterally implanted with the Acrysof IQ monofocal IOL.
View Article and Find Full Text PDFJ Mol Model
January 2025
School of Mechanics and Safety Engineering, Zhengzhou University, Zhengzhou, 450001, People's Republic of China.
Context: SiGe nanotubes (SiGeNTs) hold significant promise for applications in nanosolar cells, optoelectronic systems, and interconnects, where thermal conductivity is critical to performance. This study investigates the effects of length, diameter, temperature, and axial strain on the thermal conductivity of armchair and zigzag SiGeNTs through molecular dynamics simulations. Results indicate that thermal conductivity increases with sample length due to ballistic heat transport and decreases with temperature as phonon scattering intensifies.
View Article and Find Full Text PDFInvest Ophthalmol Vis Sci
January 2025
Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
Purpose: This study evaluates the effect of 6° horizontal gaze tolerance on visual field mean sensitivity (MS) in patients with glaucoma using a binocular head-mounted automated perimeter, following findings of structural changes in the posterior globe from magnetic resonance imaging and optical coherence tomography.
Methods: In this cross-sectional study, a total of 161 eyes (85 primary open-angle glaucoma [POAG] and 76 healthy) from 117 participants were included. Logistic regression and 1:1 matched analysis assessed the propensity score for glaucoma and healthy eyes, considering age, sex, and axial length as confounders.
Pak J Med Sci
January 2025
Sasankoti Mohan Ravi Prakash, DMD, MDS, BDS Dentist and Independent Researcher, Hope Health Inc, 360 N Irby St. Florence, South Carolina, USA 29501.
Background & Objective: Currently, there are many implants in clinical use, making it hard to choose the right one for the patient. The success rate of an implant depends on its diameter, length, and direction of insertion in bone. In implant dentistry, Finite Element Analysis (FEA) simulates intraoral conditions in vitro and analyzes the effects of implant material, diameter, size, and other components related to oral structure on the implant and peri-implant tissues.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Department of Ophthalmology, Saitama Medical Center, Saitama Medical University, Kawagoe-shi, Saitama, Japan.
Purpose: Among patients with angle-closure glaucoma, it is common to have a short-axial eye, which also makes it difficult to select an appropriate intraocular lens. Previous studies have focused on the ocular biometry of the long-axial eye, whereas only a few reports have focused on the short-axial eye. This study aimed to clarify the characteristics of the short-axial eye on ocular biometry among the elderly Japanese.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!