Objective: The objective was to quantitatively evaluate the validity of ultrasonographic (US) muscle measurements as compared to the gold standard of computed tomography (CT) in the canine.
Design: This was a prospective study.
Population: Twenty-five, client-owned dogs scheduled for CT as part of a diagnostic work-up for the management of their primary disease process were included.
Materials And Methods: Specific appendicular () and axial () muscle groups were selected for quantitative measure based on CT planning and patient position. Prior to CT scan, the skin over the muscle sites was shaved and marked with a permanent marker. Patient body position was determined based on the patient's CT plan; positioning was consistent between CT and US imaging. To ensure identical imaging position for both CT and US measurements, radio-opaque fiducial markers were placed directly over the skin marks once the dog was positioned. Quantitative measurements (cm) for both lean muscle mass (LMM) and subcutaneous adipose (SQA) were recorded. Statistical comparisons between CT and US values were done separately for each site and type.
Results: Muscle groups and associated SQA measured by US and CT were not statistically different based on an adjusted -value using Bonferroni's correction ( < 0.0031). In addition, all LMM and SQA sites had good reliability and agreement (Cronbach's = 0.8 - 1.0) between the two metrics, excluding the coxofemoral extensor muscle group (Cronbach's = 0.73232). Linear regression analysis of muscle measures indicated close agreement (slope range 0.93-1.09) and minimal bias of variation (intercept range 0.05-0.11) between CT versus US modalities, with the exception of the coxofemoral extensor muscle. Similarly, SQA CT and US measures indicated close agreement with the slope range of 0.88-1.02 and minimal bias of variation with an intercept range of 0.021-0.098, excluding the cubital flexor and extensor groups. Additionally, the values for these remaining LMM and SQA sites are reported as >0.897 for LLM and >0.8289 for SQA.
Conclusions: Ultrasound imaging of selected appendicular and axial muscle groups in dogs can provide comparable assessment of muscle thickness to the current gold standard, CT. In consideration of both statistical reliability to CT and cage-side accessibility, the and LMM sites are considered the most useful targets for US LMM assessment in the canine. Our findings support the potential utility of US as a clinical tool in veterinary medicine to assess LMM status in patients. Additional studies are indicated to develop standardized protocols of its use in a cage-side setting and to elucidate the benefit of this modality, in conjunction with nutritional interventions, to manage body LLM stores in compromised patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5270592 | PMC |
http://dx.doi.org/10.7717/peerj.2926 | DOI Listing |
Anal Chem
January 2025
Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.
Ligand binding to membrane proteins initiates numerous therapeutic processes. Surface plasmon resonance (SPR), a popular method for analyzing molecular interactions, has emerged as a promising tool for in situ determination of membrane protein binding kinetics owing to its label-free detection, high surface sensitivity, and resistance to intracellular interference. However, the excitation of SPR relies on noble metal films, typically gold, which are biologically incompatible and can cause fluorescence quenching.
View Article and Find Full Text PDFJ Am Podiatr Med Assoc
January 2025
†Jesse Brown VA Medical Center,820 S Damen Ave, Chicago, IL.
Total contact casting is the gold standard for plantar foot ulcers but has been questioned in heel pressure ulcers. Current offloading of heel ulcers is typically removable offloading boots. We describe using a modified posterior splint to offload heel ulcers in nonweightbearing patients.
View Article and Find Full Text PDFSpine Deform
January 2025
Spine Unit, Department of Orthopaedic Surgery, Institute of Orthopedics, Lerdsin Hospital, College of Medicine, Rangsit University, 190 Silom Road, Bangkok, 10500, Thailand.
Study Design: A prospective comparative study.
Objectives: To compare the curve flexibility in adolescent idiopathic scoliosis (AIS) using supine traction push-prone and push-prone traction radiographs and to determine which method is more effective in predicting the postsurgical correction.
Background: Preserving spinal motion is one of the critical objectives in adolescent idiopathic scoliosis (AIS) surgery.
Vet Res Commun
January 2025
ICAR-National Institute of Veterinary Epidemiology and Disease Informatics (NIVEDI), Post Box No. 6450, Yelahanka, Bengaluru, Karnataka, 560119, India.
Sheeppox and Goatpox are highly contagious transboundary viral diseases of sheep and goats caused by Capripoxvirus, respectively. This study describes the development of indirect ELISA and its serodiagnostic potential as an alternative to the gold standard serum neutralization test (SNT). The homologue of vaccinia virus, ORF 117 (A27L) gene of the Romanian Fenner (RF) strain of Sheeppox virus (SPPV) was used for producing the full-length recombinant A27L (rA27L) protein (∼22 kDa) in a prokaryotic expression system.
View Article and Find Full Text PDFJ Nephrol
January 2025
School of Nursing, Curtin University, Kent Street, Bentley, WA, 6102, Australia.
Background: Advanced chronic kidney disease is a life-limiting disease that is known to benefit from palliative care. Unmet palliative care need in patients with kidney failure is commonly reported but the level of need among patients receiving haemodialysis is unknown.
Methods: A period prevalence study of adult patients attending two hospital-based dialysis units was conducted.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!