In this work, a double flush-mounted probe for measuring plasma parameters was designed and fabricated. The method to determine the plasma density and electron temperature using a floating double flush-mounted probe was characterized. To validate this method, the measurement results in an argon glow discharge plasma, including the electron density and temperature measurements, were compared with those obtained using a single probe and a double probe. Results indicate that the electron density measured using the double flush-mounted probe agrees well with those measured using other probes; the effective electron temperature values are also consistent within the admissible error range. These results suggest that the double flush-mounted probe can be used for accurate measurements at low pressure DC plasma discharges and also can be applied to other complex plasmas such as tokamaks, in the boundary-layer region without a reference electrode.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4973701DOI Listing

Publication Analysis

Top Keywords

double flush-mounted
20
flush-mounted probe
20
argon glow
8
glow discharge
8
discharge plasma
8
electron temperature
8
electron density
8
probe
7
double
6
plasma
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!