Ingested or penetrating foreign bodies are common in veterinary medicine. When they are radiolucent, these objects become a diagnostic challenge, but they can be investigated sonographically. However, successful object identification depends on the skill of the sonographer. Considering that these cases appear randomly during hospital routines, it is not always possible to train all students to identify them correctly. Therefore, the aim of this study was to produce homemade simulations of radiolucent foreign bodies for veterinary student demonstrations that could be identified sonographically and to evaluate the acceptability, applicability, and usefulness of these simulations according to a visual analog scale questionnaire and subjective questions. For this purpose, object models (a pacifier nipple, a toy ball, a sock, nylon thread, and a mango seed) were designed, produced, and immersed in gelatin. To simulate wood splinters in the integumentary and musculoskeletal system, a piece of meat punctured with a toothpick and ice cream stick splinters were used. The type of phantom had a determinant effect on the visualization (chi-square = 36.528, P < 0.0001) and recognition (chi-square = 18.756, P = 0.0021) capability of the students. All of the students answered that their experience with the models could help in real situations. The student responses to the questionnaire indicated that the project was well accepted, and the participants believed that this experience could be applicable to and useful in veterinary routines.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/advan.00163.2015 | DOI Listing |
J Pediatr Ophthalmol Strabismus
January 2025
This report describes the longest case of a retained metallic intraorbital foreign body with no complications and development of delayed sensory exotropia following traumatic sclopetaria in childhood. A 9-year-old girl suffered a BB gun injury to the left eye, leading to chorioretinitis sclopetaria and loss of vision. The visual acuity was 20/800 with a relative afferent pupillary defect and choroidal rupture with subretinal hemorrhage that evolved to sclopetaria over time.
View Article and Find Full Text PDFCureus
December 2024
Department of Orthopedic Surgery, Japanese Red Cross Shizuoka Hospital, Shizuoka, JPN.
Total hip arthroplasty (THA) is a highly effective surgical intervention for end-stage hip joint disorders. While common complications such as infection, dislocation, and prosthetic loosening are well-documented, rarer complications remain underreported. One such complication is foreign body interposition on the bearing surface, which can compromise joint mechanics and adversely affect outcomes.
View Article and Find Full Text PDFBMJ Case Rep
January 2025
Pneumology, Centre Hospitalier du Valais Romand, Sion, Switzerland.
A woman in her mid-70s presented with worsening dyspnoea, cough and fatigue initially treated for pneumonia. Despite antibiotics, her condition deteriorated, prompting further investigation. Medical history included previous breast implants, the latter of which had ruptured years earlier and was subsequently removed prior to the current presentation.
View Article and Find Full Text PDFCureus
December 2024
Department of Pulmonary Medicine, All India Institute of Medical Sciences, Jodhpur, Jodhpur, IND.
Background Airway foreign body aspiration is an emergency predominantly observed in children and the elderly. However, it also occurs in adults, presenting with a variety of symptoms. Both rigid and flexible bronchoscopies are employed for foreign body retrieval.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
January 2025
From the Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA (Colin M Segovis), Department of Neuroradiology, University of Texas MD Anderson Cancer Center, Houston, Texas, USA (Jacob W Ormsby, Melissa M Chen), Department of Radiology, Indiana University School of Medicine, Indianapolis, IN, USA (Cindy X Yuan), Enterprise Radiology, Emory Healthcare, Atlanta, GA, USA (Matthew J Goette), Department of Radiology, Mayo Clinic, Rochester, MN, USA (Heidi A Edmonson).
The magnetic fields of the MR environment present unique safety challenges. Medical implants and retained foreign bodies can prevent patients from undergoing MR imaging due to interactions between the magnetic fields of the MR environment and the implant or foreign body. These hazards can be addressed through careful MR safety screening and MR examination customization, often allowing these patients with implants to undergo management-altering MR imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!