Background And Aim: In preceding studies, we identified that the myenteric plexus (MP) could be visualized with confocal laser endomicroscopy (CLE) by applying neural fluorescent probes lacking clinical safety profiling data from the submucosal side. In this study, we evaluated the technical feasibility of MP visualization using probe-based CLE (pCLE) from the serosal side with cresyl violet (CV), which has been used clinically for chromoendoscopy.
Methods: The dye affinity of CV for MP was first explored in an in vivo transgenic mouse model using neural crest derivatives labeled with green fluorescent protein. We also tested the feasibility of CV-assisted visualization of MP in human surgical specimens, wherein the tissue dying and pCLE observation were performed from the serosal side. In the human study, rate of MP visualization by pCLE was evaluated as the primary outcome. We also evaluated the sensitivity and specificity of MP visualization by pCLE, using pathological presence/absence of MP as the gold standard.
Results: We confirmed the dye affinity of CV to MP in all tested models. The MP appeared as brightly stained ladder-like structures with pCLE, and in the human study, MP was visualized in 12/14 (85.7%) samples, with 92.3% sensitivity and 100% specificity. In positive cases showing the ladder-like structure of MP by pCLE, the mean maximum and minimum widths of nerve strands were 54.3 (± 23.6) and 19.7 (± 6.0) μm, respectively. A ganglion was detected by pCLE in 10 cases (10/12, 83.3%).
Conclusions: This study demonstrated the technical feasibility of visualizing the MP in real time by CV-assisted pCLE (UMIN-CTR number, UMIN000015056).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jgh.13754 | DOI Listing |
Crit Care Explor
January 2025
Department of Mathematics and School of Biomedical Engineering, Colorado State University, Fort Collins, CO.
The purpose of this work is to evaluate the feasibility of lung imaging using 3D electrical impedance tomography (EIT) during spontaneous breathing trials (SBTs) in patients with acute hypoxic respiratory failure. EIT is a noninvasive, nonionizing, real-time functional imaging technique, suitable for bedside monitoring in critically ill patients. EIT data were collected in 24 mechanically ventilated patients immediately preceding and during a SBT on two rows of 16 electrodes using a simultaneous multicurrent source EIT system for 3D imaging.
View Article and Find Full Text PDFIntroduction: Visual Inspection with Acetic Acid (VIA) has been adopted for cervical cancer screening in Kenya and other Low-Middle Income Countries despite providing suboptimal results among HIV-infected women. It is mostly performed by nurses in health centers. Innovative ways of improving the performance of VIA in HIV-infected women are desired.
View Article and Find Full Text PDFJ Arrhythm
February 2025
Department of Cardiology Saitama Medical University, International Medical Center Hidaka Japan.
Background: A novel contact force (CF) sensing catheter with a mesh-shaped irrigation tip (TactiFlexTM SE, Abbott), is expected to provide safe and effective radiofrequency ablation. Our previous study revealed that the TactiFlex catheter needs a higher power for pulmonary vein isolation (PVI) due to the long tip length. This study aimed to examine the feasibility and safety of a 50 W ablation with the TactiFlex for PVI of atrial fibrillation (AF).
View Article and Find Full Text PDFBackground: Few clinical studies of atrial fibrillation (AF) have focused on Asian patients; data are lacking on current mapping and ablation strategies in the Asia Pacific region (APAC).
Objective: The HD Mapping Observational Study (NCT04022954) was designed to characterize electroanatomic mapping (EAM) with market-released high-density mapping (HDM) catheters in subjects with AF in APAC.
Methods: Subjects undergoing HDM and indicated for radiofrequency ablation (RFA) to treat AF were prospectively enrolled in APAC.
Am J Prev Cardiol
March 2025
Leon H. Charney Division of Cardiology, Department of Medicine, NYU Grossman School of Medicine, New York, NY, USA.
Background: Digital health technologies have been proposed as a potential solution to improving maternal cardiovascular (CV) health in the postpartum (PP) period. In this context we performed a systematic scoping review of digital health interventions designed to improve PP CV health.
Methods: We conducted a systematic review of PubMed/MEDLINE, EMBASE, CINAHL, Web of Science and the Cochrane Library.