To prospectively compare image quality and myocardial T relaxation times of modified Look-Locker inversion recovery (MOLLI) imaging at 3.0 T (T) acquired with patient-adaptive dual-source (DS) and conventional single-source (SS) radiofrequency (RF) transmission. Pre- and post-contrast MOLLI T mapping using SS and DS was acquired in 27 patients. Patient wise and segment wise analysis of T times was performed. The correlation of DS MOLLI measurements with a reference spin echo sequence was analysed in phantom experiments. DS MOLLI imaging reduced T standard deviation in 14 out of 16 myocardial segments (87.5%). Significant reduction of T variance could be obtained in 7 segments (43.8%). DS significantly reduced myocardial T variance in 16 out of 25 patients (64.0%). With conventional RF transmission, dielectric shading artefacts occurred in six patients causing diagnostic uncertainty. No according artefacts were found on DS images. DS image findings were in accordance with conventional T mapping and late gadolinium enhancement (LGE) imaging. Phantom experiments demonstrated good correlation of myocardial T time between DS MOLLI and spin echo imaging. Dual-source RF transmission enhances myocardial T homogeneity in MOLLI imaging at 3.0 T. The reduction of signal inhomogeneities and artefacts due to dielectric shading is likely to enhance diagnostic confidence.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-017-1072-8DOI Listing

Publication Analysis

Top Keywords

molli imaging
12
molli mapping
8
patient-adaptive dual-source
8
dual-source conventional
8
conventional transmission
8
imaging 30 t
8
spin echo
8
phantom experiments
8
dielectric shading
8
molli
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!