A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of different protease inhibitors on stability of parathyroid hormone, insulin, and prolactin levels under different lag times and storage conditions until analysis. | LitMetric

Introduction: Proteolytic cleavage through proteases affects peptide hormone levels, which is of particular significance when the time interval between sampling and analysis is prolonged. We evaluated the stability of parathyroid hormone, insulin, and prolactin molecules (i) with different protease inhibitors such as K EDTA, aprotinin, and protease inhibitor cocktail (PIC), (ii) with different lag times (6-72 hours), and (iii) under different storage temperatures (4°C vs room temperature [RT]) until analysis.

Materials And Methods: Blood samples were collected into 2 sets of 5 Vacutainer tubes (Becton Dickinson) from 10 healthy adults. Tubes 1 and 2 were plain gel separator tubes. Tubes 3, 4, and 5 contained PIC (1%), aprotinin (500 KIU/mL), and K EDTA, respectively. After centrifugation at 1300 g for 10 minutes, PIC added to tube 2 of each set. Samples were analyzed and then one set was stored at 4°C, whereas the other at RT until analysis at 6, 24, 48, and 72 hours. Hormone levels were determined with electrochemiluminescence immunoassay (ModularE170; Roche Diagnostics). The results were compared with desirable bias limits (DBL) from Westgard QC database.

Results: Insulin at RT decreases exceeding the DBL starting from 24 hours and K EDTA preserved insulin. PTH exceeded the DBL at RT for 48 hours or longer and PIC addition after centrifugation inhibited its degradation. Prolactin remained stable in all tested conditions. All parameters in the plain gel separator tubes remained within DBL when stored at 4°C until 72 hours.

Conclusions: Different proteases may degrade peptide hormones and measures should be taken to counteract these effects especially if there is a delay before analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6817059PMC
http://dx.doi.org/10.1002/jcla.22144DOI Listing

Publication Analysis

Top Keywords

protease inhibitors
8
stability parathyroid
8
parathyroid hormone
8
hormone insulin
8
insulin prolactin
8
lag times
8
hormone levels
8
plain gel
8
gel separator
8
separator tubes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!