  • This study examined how different depths of guidewire insertion affect the incidence of arrhythmias during central venous catheterization in 69 elective surgery patients.
  • A significant 42% of patients experienced arrhythmic episodes, with higher rates in those whose guidewires were inserted to 20cm (65%) compared to 15cm (26%) and 17.5cm (35%).
  • The findings suggest that inserting guidewires only to 15cm or 17.5cm can lower the risk of arrhythmias compared to a depth of 20cm.

Article Abstract

Objective: Guidewire-induced arrhythmias that occur during central venous catheterization can progress to malignant arrhythmias in rare cases. This study compared the incidence of arrhythmia during central venous catheterization using three different depths of guidewire insertion into the right internal jugular vein.

Methods: Sixty-nine patients undergoing elective surgery requiring central venous catheterization through the right internal jugular vein were enrolled in this double-blind, prospective, randomized, and controlled study. Patients were randomly allocated to receive guidewire insertions to 15cm, 17.5cm, or 20cm before tissue dilation. Arrhythmic episodes were then monitored during dilation of the soft tissue.

Results: A total of 29 patients (42%) experienced arrhythmic episodes during tissue dilation. The guidewire-induced arrhythmia rates of the 15cm group, 17.5cm group, and 20cm group were 0.26 (95% confidence interval [CI]=0.10, 0.48), 0.35 (95% CI=0.16, 0.57), and 0.65 (95% CI=0.43, 0.84), respectively. The incidence of arrhythmic episodes was higher in the 20cm group than in the 15cm (odds ratio [OR]=5.31; 95% CI=1.50, 18.84) and 17.5cm (OR =3.52; 95% CI=1.05, 11.83) groups. There was no significant difference in arrhythmia rates between the 15cm group and 17.5cm group (p=0.542).

Conclusions: During central venous catheterization through the right internal jugular vein, inserting guidewires to depths of 15 or 17.5cm before tissue dilation reduced the incidence of arrhythmic episodes compared to a depth of 20cm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajem.2017.01.016DOI Listing

Publication Analysis

Top Keywords

central venous
20
venous catheterization
20
arrhythmic episodes
16
internal jugular
12
tissue dilation
12
guidewire insertion
8
incidence arrhythmia
8
arrhythmia central
8
catheterization internal
8
jugular vein
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!