A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cartilage thickness of distal humerus and its relationships with bone dimensions: magnetic resonance imaging bilateral study in healthy elbows. | LitMetric

Background: Little is known about the cartilage thickness of the distal humerus and how it affects the shape of the articular surface. Our aims were to assess cartilage thickness and to determine the extent to which it affects the true profile of the distal humerus.

Methods: We assessed 78 healthy elbows (39 subjects, 19 women and 20 men) with a mean age of 28 years (range, 21-32 years). Cartilage thickness was measured by use of high-definition magnetic resonance imaging scans at 19 different points of the articular surface, 13 on the trochlea and 6 on the capitellum, on the axial and coronal views. Bone diameters at the medial and lateral trochlear ridges, trochlear groove, and capitellum, as well as the articular surface width, were measured. Subject height was used as an indirect measurement of humerus length. Pearson correlation coefficients and the Student t test were used.

Results: Cartilage thickness showed a significant variation (range, 0.4-1.8 mm) independent of sex and side. It appeared thinner at the medial and lateral edges, whereas it increased at the level of the trochleocapitellar and trochlear grooves, the lateral trochlear ridges, and the center of the capitellum. The mean bone diameters of the medial ridge, lateral ridge, trochlear groove, and capitellum measured 25.1 mm, 21 mm, 16.9 mm, and 19.6 mm, respectively. The mean width of the articular surface was 42.9 mm (range, 35.8-50.2 mm). No significant correlation was found between cartilage thickness and bone dimensions.

Conclusion: Cartilage thickness is not uniform and modifies the morphologic shape and diameters of the humeral articular surface. These findings may be relevant to anatomic prosthesis design.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2016.10.012DOI Listing

Publication Analysis

Top Keywords

cartilage thickness
28
articular surface
20
thickness distal
8
distal humerus
8
magnetic resonance
8
resonance imaging
8
healthy elbows
8
bone diameters
8
diameters medial
8
medial lateral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!