A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Precision of Epithelial Defect Measurements. | LitMetric

Precision of Epithelial Defect Measurements.

Cornea

Department of Ophthalmology and Visual Sciences, W.K. Kellogg Eye Center, University of Michigan Medical School, Ann Arbor, MI.

Published: April 2017

Purpose: To ensure optimal care of patients, cornea specialists measure corneal features, including epithelial defects (ED), with slit-lamp calipers. However, caliper measurements are subject to interphysician variability. We examined the extent of variability in ED measurements between cornea specialists and discuss the potential clinical impact.

Methods: A total of 48 variably sized EDs were created in pig eyes. Three cornea specialists measured the maximum vertical and horizontal ED lengths to the nearest 10th of a millimeter using slit-lamp microscopy. An absolute difference in ED measurement between cornea specialists of 0.5 mm was chosen to be the a priori threshold for clinical significance and was evaluated by the Wilcoxon signed-rank test. Interrater reliability was assessed by intraclass correlation coefficients.

Results: The average absolute difference in the vertical ED length between pairs of examiners ranged from 0.54 to 0.63 mm, and that of the horizontal ED length ranged from 0.44 to 0.46 mm. These differences in ED measurement were not significantly different from 0.5 mm (all P > 0.06). However, pairs of examiners differed in vertical ED length measurements by >0.5 mm in 44% to 52% of EDs and by >1.0 mm in 13% to 17% of EDs. Pairs of examiners differed in horizontal ED length measurements by >0.5 mm in 31% to 40% of EDs and by >1.0 mm in 10% to 15% of EDs. The intraclass correlation coefficient was 0.85 (95% confidence interval, 0.77-0.91) for vertical and 0.84 (95% confidence interval, 0.74-0.90) for horizontal ED measurements.

Conclusions: Cornea specialists showed good reliability in the measured EDs; however, depending on the threshold for clinical significance, a nontrivial percentage of cases have high interexaminer clinical variability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5517027PMC
http://dx.doi.org/10.1097/ICO.0000000000001148DOI Listing

Publication Analysis

Top Keywords

cornea specialists
20
pairs examiners
12
absolute difference
8
threshold clinical
8
clinical significance
8
intraclass correlation
8
vertical length
8
horizontal length
8
examiners differed
8
length measurements
8