Surgical repair of larger peripheral nerve lesions requires the use of autologous nerve grafts. At present, clinical alternatives to avoid nerve transplantation consist of empty tubes, which are only suitable for the repair over short distances and have limited success. We developed a cell-free, three-dimensional scaffold for axonal guidance in long-distance nerve repair. Sub-micron scale fibres of biodegradable poly-ε-caprolactone (PCL) and collagen/PCL (c/PCL) blends were incorporated in a gelatin matrix and inserted in collagen tubes. The conduits were tested by replacing 15-mm-long segments of rat sciatic nerves in vivo. Biocompatibility of the implants and nerve regeneration were assessed histologically, with electromyography and with behavioural tests for motor functions. Functional repair was achieved in all animals with autologous transplants, in 12 of 13 rats that received artificial implants with an internal structure and in half of the animals with empty nerve conduits. In rats with implants containing c/PCL fibres, the extent of recovery (compound muscle action potentials, motor functions of the hind limbs) was superior to animals that had received empty implants, but not as good as with autologous nerve transplantation. Schwann cell migration and axonal regeneration were observed in all artificial implants, and muscular atrophy was reduced in comparison with animals that had received no implants. The present design represents a significant step towards cell-free, artificial nerve bridges that can replace autologous nerve transplants in the clinic. Copyright © 2017 John Wiley & Sons, Ltd.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/term.2237 | DOI Listing |
Distal tibial fractures are common lower-limb injuries and are generally associated with a high risk of postoperative complications, especially in patients with multiple medical comorbidities. This study sought to ascertain the efficacy of retrograde intramedullary tibial nails (RTN) for treating extra-articular distal tibial fractures in high-risk patients. Between January 2019 and December 2021, 13 patients considered at high risk for postoperative complications underwent RTN fixation.
View Article and Find Full Text PDFThe aim of this study was to investigate the effect of the presence of the "cortex sign" (corticalization) in femoral diaphysis fractures determined by the dynamization of nails because of delayed union. The study included 12 patients with a closed transverse femoral fracture (AO 32a3) treated with dynamization (all the screws distal of the nail were removed) because of delayed healing and followed up for at least 2 years. These patients were evaluated for the presence of bone union, cortex-like sclerosis (corticalization) distal to the nail, and the distance of the corticalization from the joint during follow- up after dynamization.
View Article and Find Full Text PDFCephalomedullary nail is the gold standard treatment for intertrochanteric fracture in geriatric population. The aim of the study was to investigate the differences of the reamed versus the unreamed short proximal femoral nailing (PFN), in terms of the duration of surgery and the outcome. The impact of patients and fracture characteristics to the outcome was also evaluated.
View Article and Find Full Text PDFClavicle fractures represent one of the most frequent type of fractures. However, there is no consensus on the treatment of these fractures and their relative indications for surgery. The purpose of this study is to determine whether surgical treatment of mid-diaphyseal clavicular fractures indeed results in fewer complications and better radiological outcomes, as current trends suggest, in comparison to conservative treatment.
View Article and Find Full Text PDFActa Orthop Belg
September 2024
The aim of this study is to investigate whether not using the calcar screw in proximal humerus fractures affects functional and radiological outcomes. Thirty patients (21 females and 9 males) who presented with proximal humerus fractures and were treated with plate- screw fixation were evaluated. The patients were divided into two groups: group 1 included patients with the use of the calcar screw, and group 2 included patients without the calcar screw.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!