Background: The current standard for confirmation of correct supra-diaphragmatic central venous catheter (CVC) placement is with plain film chest radiography (CXR). We hypothesized that a simple point-of-care ultrasound (POCUS) protocol could effectively confirm placement and reduce time to confirmation.
Methods: We prospectively enrolled a convenience sample of patients in the emergency department and intensive care unit who required CVC placement. Correct positioning was considered if turbulent flow was visualized in the right atrium on sub-xiphoid, parasternal or apical cardiac ultrasound after injecting 5 cc of sterile, non-agitated, normal saline through the CVC.
Results: Seventy-eight patients were enrolled. POCUS had a sensitivity of 86.8% (95% 77.1%-93.5%) and specificity of 100% (95% 15.8%-100.0%) for identifying correct central venous catheter placement. Median POCUS and CXR completion were 16 minutes (IQR 10-29) and 32 minutes (IQR 19-45), respectively.
Conclusion: Ultrasound may be an effective tool to confirm central venous catheter placement in instances where there is a delay in obtaining a confirmatory CXR.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5263031 | PMC |
http://dx.doi.org/10.5847/wjem.j.1920-8642.2017.01.004 | DOI Listing |
Open Vet J
November 2024
Department of Pathology and Poultry Disease, College of Veterinary Medicine, University of Diyala, Baqubah, Iraq.
Background: Pollution of aquatic environments with heavy metals causes severe adverse effects on fish, invertebrates, and human. The importance of this study lies in the fact that long-term ingestion of heavy metal-contaminated fish can result in the accumulation of harmful metals in numerous organs and pose a major risk to human health.
Aim: The current study was designed to investigate the concentrations of toxic arsenic (As), lead (Pb), and mercury (Hg) in the liver, gills, and muscles of highly consumed aqua cultured common carp ( L.
BMC Musculoskelet Disord
December 2024
Department of Surgery, Hospital Nova of Central Finland, Wellbeing Services County of Central Finland, Jyväskylä, University of Eastern Finland, Kuopio, Finland.
Background: The optimal length of thromboprophylaxis after total hip or knee arthroplasty (THA and TKA) is unknown. Fast-track protocols have improved patient care and led to shorter immobilization and length of stay (LOS) after THA and TKA, thereby diminishing venous thromboembolism (VTE) risk. Here, we investigated risk stratification-based thromboprophylaxis after fast-track THA and TKA.
View Article and Find Full Text PDFCureus
November 2024
Anesthesiology, Anesthesia Unit, National Cancer Institute, Santiago, CHL.
Background: Totally implantable venous access devices (TIVADs) are widely used in oncology patients to facilitate central venous access. Although they offer benefits, TIVADs can be associated with complications.
Materials And Methods: This retrospective cohort study included all oncology patients 18 years or older who underwent TIVAD implantation between September 2015 and October 2019.
J Geriatr Cardiol
November 2024
Department of Anesthesiology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, Japan.
Turk J Med Sci
December 2024
Division of General Surgery, Department of Surgery, Institute of Oncology, İstanbul University, İstanbul, Turkiye.
Background/aim: To investigate the possible morbidities associated with the implantation of a totally implantable venous access device (TIVAD) in breast cancer (BC) patients.
Materials And Methods: Clinical data and developed complications in 546 BC patients with TIVAD between 2017 and 2021 were analyzed retrospectively. Among these, 524 (96%) patients who underwent TIVAD implantation via the right subclavian vein (SCV) route were examined separately.