Background: The aim of our study was to assess how a preoperative computed tomography (CT)-based navigation system affected the correctness and safety of transpedicular screw insertion, compared with standard techniques.

Method: Between January 2012 and February 2014, 203 patients underwent thoracic and lumbar fixation, with open and percutaneous techniques; 218 screws were implanted through an open navigated technique (1.0 Spine & Trauma 3d ver. 2.0 BrainLab, Feldkirchen Germany) in 43 patients; 220 screws were inserted with an open free-hand technique in 45 patients; 230 screws were implanted in 56 patients using percutaneous CT-based navigation; and 236 screws were inserted in 59 patients using a percutaneous fluoroscopy-guided technique. To our knowledge, this is the first work comparing these four different techniques. The position of each screw was evaluated on CT scan reconstruction and classified according to a four-point grading scale (grade 0: no breach, grade 1: breach < 2 mm, grade 2: breach between 2 and 4 mm; grade 3: breach >4 mm). Statistical analysis was assessed by two-way analysis of variance (ANOVA) t test, while the Fisher least significant difference (LSD) method was employed to determine statistical significance.

Results: Statistical analysis showed a significant difference in accuracy between the open CT-based navigation and the percutaneous CT-based navigation techniques (P= 0.0263) and between the open CT-based navigation and the percutaneous fluoroscopy-guided techniques (P=0.0258): a particular difference was observed in anterior misplacement between open CT-based navigation and the percutaneous fluoroscopy-guided technique (P= 0.0153).

Conclusions: Our results confirm the advantages of the navigation technique, which ensures greater accuracy, in open as well as percutaneous procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-3-319-39546-3_42DOI Listing

Publication Analysis

Top Keywords

ct-based navigation
24
grade breach
16
percutaneous fluoroscopy-guided
12
breach grade
12
open ct-based
12
navigation percutaneous
12
navigation
8
percutaneous
8
open
8
screws implanted
8

Similar Publications

Aims: Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.

Methods: We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan.

View Article and Find Full Text PDF

Introduction: Leg length is an important consideration in total hip arthroplasty (THA) as leg length discrepancies (LLD) after THA cause poor outcomes and medical litigation. This study aimed to investigate the accuracy of computed tomography (CT)-based navigation with augmented reality (AR) technology for measuring intra-operative leg length change using anteroposterior radiography (two-dimensional, 2D) and CT (three-dimensional, 3D).

Materials And Methods: This study included 71 patients (75 hips) who underwent primary cementless THA in the supine position between June 2022 and November 2023 using the HoloNavi One.

View Article and Find Full Text PDF

Background: Dislocation is a major complication of total hip arthroplasty (THA). This study aimed to assess the dislocation rate after THA using the combined strategy of using CT-based navigation, large diameter heads, and posterior soft tissue repair in a large cohort.

Methods: We included 1410 patients who had undergone primary cementless THA using the CT-based navigation system.

View Article and Find Full Text PDF
Article Synopsis
  • * No significant bleeding occurred during the operation, and the total radiation dose was recorded at 384 mGy.
  • * Postoperatively, the patient recovered well with minimal sputum blood and no major complications; a follow-up CT confirmed the successful ablation of the nodule.
View Article and Find Full Text PDF

Background: A robotic arm-assisted and a computed tomography (CT)- based navigation system have been reported to improve the accuracy of component positioning in total hip arthroplasty (THA). However, no study has compared robotic arm-assisted THA (rTHA) to CT-based navigated THA (nTHA) concerning accuracy of cup placement and acetabular fractures using the direct anterior approach (DAA). This study aimed to compare the accuracy of cup placement and the presence of intraoperative acetabular fractures between rTHA and nTHA using DAA in the supine position.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!