We report the rare case of an in situ fracture of a spinal needle within the setting of repeated caesarean delivery in a 28-year-old pregnant woman and discuss the responsible underlying factors. In particular, a wrong technique, limited experience, difficulties to identify the anatomical landmarks, as well as the use of spinal needles smaller than 25 G might promote such a complication. In order to ensure the stability of the spinal needle and to avoid an in situ fracture, the spinal needle should be never moved without the stylet. In case of repeated bone contact, a well-experienced anaesthetist should be consulted, the spinal needle should be replaced and the use of ultrasound is recommended. Next, the use of an atraumatic spinal needle greater than 27 G should be considered to facilitate intrathecal puncture and to avoid the in situ fracture of a spinal needle. Within this context, the risk of post-spinal puncture headache should be balanced. If an in situ fracture of a spinal needle happens, its subsequent removal should be planned without delay by an interdisciplinary team and the anaesthetic method should be chosen with consideration of patient-specific risk factors.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00101-017-0266-8DOI Listing

Publication Analysis

Top Keywords

spinal needle
20
situ fracture
16
fracture a spinal
12
a spinal needle
12
needle
8
repeated caesarean
8
caesarean delivery
8
avoid situ
8
spinal
6
[in situ
4

Similar Publications

Purpose: Spinal cord stimulation (SCS) is pivotal in treating chronic intractable pain. To elucidate the mechanism of action among conventional and current novel types of SCSs, a stable and reliable electrophysiology model in the consensus animals to mimic human SCS treatment is essential. We have recently developed a new in vivo implantable pulsed-ultrahigh-frequency (pUHF) SCS platform for conducting behavioral and electrophysiological studies in rats.

View Article and Find Full Text PDF

Duhuo Jisheng Mixture attenuates neuropathic pain by inhibiting S1PR1/P2YR pathway after Chronic Constriction Injury in mice.

Phytomedicine

January 2025

Department of Pharmacy, Xijing Hospital, Fourth Military Medical University, Changle West Street 15, Xi'an, Shaanxi, 710032, China. Electronic address:

Background: The pathogenesis of neuropathic pain is complex and lacks effective clinical treatment strategies. Medical plants and herbal extracts from traditional Chinese medicine with multi-target comprehensive effects have attracted great attention from scientists.

Purpose: To investigate the pharmacological active components and mechanism underlying the anti-neuralgia effect of classic analgesic formulas Duhuo Jisheng Mixture (DJM).

View Article and Find Full Text PDF

Ultrasound Evaluation of Upper Limb Sublesional Muscle Morphology in Cervical Spinal Cord Injury.

Muscle Nerve

January 2025

International Collaboration on Repair Discoveries (ICORD), Vancouver, British Columbia, Canada.

Introduction/aims: Upper limb paralysis is arguably the most limiting consequence of cervical spinal cord injury (cSCI). There is limited knowledge regarding the early structural changes of muscles implicated in grasp/pinch function and upper extremity nerve transfer surgeries. We evaluated: (1) muscle size and echo intensity (EI) in subacute cSCI (2-6 months) and (2) the influence of lower motor neuron (LMN) damage on these ultrasound parameters.

View Article and Find Full Text PDF

In vivo Safety and Feasibility of a Computed Tomography-Guided Robotic Device for Percutaneous Needle Placement in Bone.

J Vasc Interv Radiol

January 2025

Gustave Roussy (GR), Département d'Anesthésie Chirurgie et Interventionnelle (DACI), Service d'Imagerie Thérapeutique, Villejuif France; Centre d'Investigation Clinique BIOTHERIS, INSERM CIC1428, Villejuif, France; Radiologie Interventionnelle, Gustave Roussy, Villejuif, France; Laboratoire de Recherche Translationnelle en Immunothérapie (LRTI), INSERM U1015, Villejuif, France; Faculté de Médecine, Paris-Saclay Université, F-94276 Le Kremlin Bicêtre, France.

Purpose: To evaluate the feasibility and accuracy of a robotic device used clinically in soft tissues (abdomen and lung), modified in design and workflow, to perform needle insertion in percutaneous bone procedures.

Methods: The primary objective was safety (severe complications) of robotic-assisted insertion in this new application. Secondary objectives were feasibility (placement technical success), performance (acceptable insertions rate), accuracy (lateral deviation), number of intermediate CT-scans and tolerance (minor/moderate complications).

View Article and Find Full Text PDF

Background: This study aimed to evaluate the efficacy of metagenomic next-generation sequencing (mNGS) technology for identifying pathogens associated with spinal infection (SI).

Methods: A retrospective analysis was conducted on clinical data from 193 patients with suspected SI between August 2020 and September 2024. Based on histopathological results, the patients were divided into the SI group (n=162) and the non-SI group (n=31).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!