A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid direct detection of carbapenemase-producing Enterobacteriaceae in clinical urine samples by MALDI-TOF MS analysis. | LitMetric

Objectives: Development of an automated MALDI-TOF MS-based method for the rapid, direct detection of carbapenemase-producing Enterobacteriaceae in clinical urine samples within 90 min of sample reception.

Methods: A total of 3041 urine samples were processed by flow cytometry, and a cut-off value of ≥1.5 × 10 5 bacteria/mL was used to select samples for the study. Following these criteria, 608 samples were selected for direct bacterial identification. Detection of carbapenemase activity by MALDI-TOF MS analysis was only performed after reliable direct identification of Gram-negative bacilli. A novel protocol was developed for extracting bacteria from urine samples by using the Sepsityper Kit (Bruker Daltonik, Germany). Carbapenem resistance was detected with imipenem as an antibiotic marker and the results were automatically interpreted using the STAR-BL module of MALDI-TOF Biotyper Compass software (Bruker Daltonik, Germany).

Results: The MALDI-TOF MS-based assay yielded direct reliable identification of 91% (503/553) of the samples. The assay showed 100% sensitivity (30/30) and specificity (454/454) for detecting carbapenemase activity within 90 min of sample reception. Isolates included in the study were further characterized by PCR and sequencing, and bla OXA-48 was detected from all isolates that tested positive in the MALDI-TOF MS-based resistance assay.

Conclusions: The proposed protocol for the direct analysis of urine samples by MALDI-TOF MS is suitable for use in clinical laboratories to identify bacteria and detect carbapenemase activity, thus saving at least 24-48 h relative to current routine methods.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jac/dkw579DOI Listing

Publication Analysis

Top Keywords

urine samples
20
maldi-tof ms-based
12
carbapenemase activity
12
rapid direct
8
direct detection
8
detection carbapenemase-producing
8
carbapenemase-producing enterobacteriaceae
8
enterobacteriaceae clinical
8
clinical urine
8
samples
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!