MitraClip therapy has been proposed as therapeutic option in selected patients with degenerative or functional mitral regurgitation (FMR), leading to clinical and prognostic benefits. Previous studies demonstrated the safety and the efficacy of MitraClip therapy on symptoms and left ventricular remodeling in cardiac resynchronization therapy (CRT) non-responder patients. We report a case of a CRT non-responder patient treated with MitraClip implantation followed by a new upgrading of the CRT for persistent FMR at the follow-up. The optimization of the interventricular delay, guided by echocardiographic parameters, resulted in a significant clinical and functional benefit. Echo-guided CRT upgrading can provide additive efficacy for patients in whom MitraClip implantation does not significantly improve FMR and symptoms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.carrev.2017.01.006 | DOI Listing |
Cardiovasc Interv Ther
January 2025
Heart Valve Center, IRCCS San Raffaele, Milan, Italy.
Background: Treatment of residual mitral regurgitation (MR) with different percutaneous devices after transcatheter edge-to-edge repair (TEER) has been reported as an alternative option to reclipping or surgery. This review aims at describing the different transcatheter strategies available and their results when managing residual MR after TEER.
Methods: A literature search was undertaken across Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases, to identify article reporting patients with post-TEER residual MR managed by a transcatheter approach that did not involve only the implantation of new clips.
BMC Cardiovasc Disord
January 2025
Department of Cardiology, Peking University International Hospital, Life Park Road No.1, Life Science Park of Zhongguancun, Chang Ping District, Beijing, 102206, China.
Background: The transcatheter edge-to-edge repair (TEER) technique, facilitated by the MitraClip device, is a minimally invasive intervention designed for high-risk patients with mitral regurgitation (MR). This study conducts a retrospective analysis of death events associated with MitraClip implantation over a ten-year decade, utilizing data from the FDA's Manufacturer and User Facility Device Experience (MAUDE) database to evaluate trends in safety outcomes.
Methods: A comprehensive search of the publicly accessible MAUDE database was conducted to retrieve reports of deaths and injuries related to MitraClip implantation from October 2013 to September 2023.
Acta Cardiol
January 2025
Cardiology, AZ Groeninge, Kortrijk, Belgium.
Objectives: Edge-to-edge mitral valve repair with MitraClip leads to a differed flow pattern and a decreased flow velocity at the left ventricle apex. This combination may lead to initiation of thrombus formation, especially in patients with severely reduced ejection fraction. The prevalence and mechanism of left ventricular thrombus formation after MitraClip implantation is still unknown.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Internal Medicine II, Städtisches Klinikum Solingen, Solingen, Germany.
Cardiovasc Eng Technol
December 2024
Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, USA.
Purpose: Advancements in minimally invasive technologies to decrease postoperative morbidity and recovery times represent a large opportunity for mitral valve repair operations. However, current technologies are unable to replicate gold standard surgical neochord implantation.
Methods: We developed a novel neochordal repair device, Minimally Invasive Ventricular Anchoring Neochordoplasty (MIVAN), which operates via transcatheter, trans-septal anchoring to the posterior ventricular wall.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!