Aims: The impact of left ventricular outflow tract calcification (LVOT-CA) on SAPIEN 3 transcatheter aortic valve replacement (S3-TAVR) is not well understood. The aims of the present study were to determine optimal device sizing for S3-TAVR in patients with or without LVOT-CA and to evaluate the influence of residual paravalvular leak (PVL) on survival after S3-TAVR in these patients.
Methods And Results: This study analysed 280 patients (LVOT-CA=144, no LVOT-CA=136) undergoing S3-TAVR. Optimal annular area sizing was defined as % annular area sizing related to lower rates of ≥mild PVL. Annular area sizing was determined as follows: (prosthesis area/CT annulus area-1)×100. Overall, ≥mild PVL was present in 25.7%. Receiver operating characteristic curve analysis for prediction of ≥mild PVL in patients with LVOT-CA showed that 7.2% annular area sizing was identified as the optimal threshold (area under the curve [AUC] 0.71). Conversely, annular area sizing for no LVOT-CA appeared unrelated to PVL (AUC 0.58). Aortic annular injury was seen in four patients (average 15.5% annular area oversizing), three of whom had LVOT-CA. Although there was no difference in one-year survival between patients with ≥mild PVL and without PVL (log-rank p=0.91), subgroup analysis demonstrated that patients with ≥moderate LVOT-CA who had ≥mild PVL had lower survival compared to patients with ≥mild PVL and none or mild LVOT-CA (log-rank p=0.010).
Conclusions: In the setting of LVOT-CA, an optimally sized S3 valve is required to reduce PVL and to increase survival following TAVR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4244/EIJ-D-16-00806 | DOI Listing |
Eur Heart J Case Rep
January 2025
HerzZentrum Hirslanden, 8032 Zurich, Switzerland.
Background: Mitral annular calcification (MAC) is characterized by severe calcification of mitral annulus and might be associated with both mitral regurgitation and stenosis. It is technically challenging for both surgical and percutaneous approach and is burdened by high mortality.
Case Summary: The present case report describes a complex case of mitral steno-insufficiency (baseline transvalvular gradient = 5 mmHg, effective regurgitant orifice area 0.
J Mech Behav Biomed Mater
December 2024
Department of Mechanical Engineering, The University of Texas at Austin, 204 E. Dean Keeton Street, Austin, TX, 78712, USA; Department of Aerospace Engineering & Engineering Mechanics, The University of Texas at Austin, 2617 Wichita Street, Austin, TX, 78712, USA; Department of Biomedical Engineering, The University of Texas at Austin, 107 W. Dean Keeton Street, Austin, TX, 78712, USA; The Oden Institute for Computational Engineering & Sciences, The University of Texas at Austin, 201 E. 24th Street, Austin, TX, 78712, USA. Electronic address:
Transcatheter edge-to-edge repair (TEER) simulations may provide insight into this novel therapeutic technology and help optimize its use. However, because of the relatively short history and technical complexity of TEER simulations, important questions remain unanswered. For example, there is no consensus on how to handle the annular boundary conditions in these simulations.
View Article and Find Full Text PDFCureus
November 2024
Cardiovascular Surgery, Sapporo Medical University, Sapporo, JPN.
We report a 75-year-old female with a history of two heart operations: aortic valve replacement (St. Jude Medical 21 mm) at the age of 44 years for severe rheumatic aortic stenosis and mitral valve replacement (Carbomedics 29 mm) at the age of 51 years for rheumatic mitral regurgitation. Decades later, she presented with exertional dyspnea.
View Article and Find Full Text PDFJ Cardiothorac Surg
December 2024
Department of Cardiology, Thomas Jefferson University, Philadelphia, PA, 19107, USA.
Background: Right ventricular (RV) function assessment by echocardiography can be challenging due to its complex morphology. Also, increasing use of sedation rather than general anesthesia for transfemoral approach transcatheter aortic valve replacement (TAVR) reduces the need for intraoperative transesophageal echocardiography (TEE). Recent clinical studies have demonstrated the importance of 3-dimensional (3D) echocardiography and a longitudinal strain for RV function assessment.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Radiology, the Affiliated Taian City Central Hospital of Qingdao University, Tai'an, 271099, China.
This study aimed to investigate the correlation between baseline MRI features and baseline carcinoembryonic antigen (CEA) expression status in rectal cancer patients. A training cohort of 168 rectal cancer patients from Center 1 and an external validation cohort of 75 rectal cancer patients from Center 2 were collected. A nomogram was constructed based on the training cohort and validated using the external validation cohort to predict high baseline CEA expression in rectal cancer patients.