A specific, sensitive, and reliable high performance liquid chromatography with fluorescence detection (HPLC-FLD) was first optimized and then used in the simultaneous quantification of bergapten, imperatorin, notopterol, and isoimperatorin in rat plasma using osthole as the internal standard. Liquid-liquid extraction with ethyl acetate was employed in treating the rat plasma samples obtained. Separation was carried out with a Hedera™ ODS column (4.6 × 250 mm, 5 m) by gradient elution at a temperature of 40°C. Excitation and emission of the fluorescence detector were set to 300 and 490 nm, respectively. The lower limits of quantification for bergapten, imperatorin, notopterol, and isoimperatorin in rat plasma were 4, 40, 4, and 2 ng mL, respectively. The intraday and interday precision and accuracy for the four coumarins were within acceptable criteria. The recovery of the method was satisfactory with a range of 80.3-114%. The validated method was successfully used for the simultaneous determination of the four coumarins in extracts and also for the pharmacokinetic and excretion study of bergapten, imperatorin, notopterol, and isoimperatorin in rats.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5220503PMC
http://dx.doi.org/10.1155/2016/9507246DOI Listing

Publication Analysis

Top Keywords

bergapten imperatorin
16
imperatorin notopterol
16
notopterol isoimperatorin
16
rat plasma
16
isoimperatorin rat
12
simultaneous determination
8
high performance
8
performance liquid
8
liquid chromatography
8
chromatography fluorescence
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!