106Ru/106Rh is unique amongst other commonly used beta sources such as 147Pm, 85Kr, 204Tl, 32P, natU and 90Sr/90Y in the sense that it is capable of simultaneously delivering shallow/skin, eye lens and deep/whole body doses (WBDs) and they differ from each other substantially. In view of this, the investigation of various quantities defined for individual monitoring is possible and this makes 106Ru/106Rh beta source, a classical example in radiation protection and dosimetry. This led us to estimate skin, eye lens and WBDs for 106Ru/106Rh beta source. Optically stimulated luminescence based ultra-thin α-Al2O3:C disc dosimeters were used in the present study. Typical values (relative) of the eye lens and whole body/deep doses with respective to the skin dose (100%) were experimentally measured as ~66 ± 4.6% and 17 ± 3.9%, respectively. The study shows that 106Ru/106Rh beta source is capable of delivering even WBD which is not the case with other beta sources.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncw383 | DOI Listing |
Ophthalmic Physiol Opt
January 2025
Faculty of Health, Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Chelmsford, UK.
Purpose: To investigate the influence of axial length on different ocular parameters and create a predictive tool for refractive error progression.
Methods: Two eye models were used to simulate refractive errors, namely the Liou-Brennan and the Goncharov-Dainty. Both models were simulated using Zemax OpticStudio.
Curr Eye Res
January 2025
Sussex Eye Hospital, Brighton & Sussex University Hospitals NHS Trust, Brighton, UK.
Purpose: To assess the relationship between angle kappa (apparent chord mu) and ocular parameters in cataract patients.
Methods: In this cross-sectional study, the data on apparent chord mu, age, axial length, anterior chamber depth, anterior and posterior mean keratometry, mean total keratometry, white-to-white, central corneal thickness and lens thickness were collected for consecutive cataract patients. Correlation (Pearson) between chord mu and the other ocular parameters was calculated.
Clin Exp Optom
January 2025
Department of Optometry, School of Paramedical and Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.
Clinical Relevance: The vestibular-ocular reflex stabilises the retinal image and maintains balance during head movement. Astigmatism is one of the common refractive errors that can reduce the quality of visual inputs.
Background: The purpose of this study was to investigate the effect of induced astigmatism on the function of the vestibular-ocular reflex.
GMS Ophthalmol Cases
December 2024
Department of Ophthalmology, Disha Eye Hospital, Siliguri, India.
Background: Pseudophakic cystoid macular edema (CME) following primary anterior-chamber intraocular lens (ACIOL) implantations is commonly seen. Intravitreal triamcinolone acetonide (IVTA) injections have shown significant improvement in visual acuity and retinal thickness in refractory pseudophakic CME. Pseudohypopyon following IVTA injection is a known entity.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Ophthalmology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Xuhui District, Shanghai, 200031, China.
Background: To investigate the impact of central corneal astigmatism on postoperative visual outcomes in patients with trifocal intraocular lens (IOL) implantation.
Methods: This retrospective study included 278 eyes of 278 patients who underwent uneventful cataract surgery with implantation of the trifocal IOL (AT LISA tri 839MP). Patients were divided into two groups according to the total corneal refractive power (TCRP) in 3 mm zone centered on the corneal apex: low astigmatism group, TCRP ≤ 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!