A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Myocardial Recovery Strategy with Decommissioning for the HeartWare Left Ventricular Assist Device. | LitMetric

Myocardial Recovery Strategy with Decommissioning for the HeartWare Left Ventricular Assist Device.

ASAIO J

From the *Department of Cardiology Freeman Hospital and †Institute of Genetic Medicine, Newcastle University, United Kingdom; and ‡Department of Cardiothoracic Surgery and §Department of Microbiology, Freeman Hospital, Newcastle upon Tyne, United Kingdom.

Published: January 2018

To manage myocardial recovery in patients with the HeartWare left ventricular assist device (HVAD), we describe a minimally invasive approach (decommissioning) that involves disconnecting the driveline and occluding the outflow tract through a small left thoracotomy incision, leaving the device in situ, in conjunction with optimal medical therapies and comprehensive assessment of left ventricular recovery. Nine patients (all male, 37 ± 12 years, all nonischemic dilated cardiomyopathy) had an HVAD implanted for 766 ± 343 days. When left ventricular function improved to mild impairment by echocardiography, patients underwent assessment at reduced flow (2578 ± 148 to 1822 ± 67 rpm) with documentation of compensated right heart hemodynamics and ejection fraction 52 ± 8%. Eight of nine patients underwent decommissioning, and 1 patient had a hybrid procedure of percutaneous occlusion of outflow graft and surgical division of driveline. Two patients died postoperatively at 413 days (sepsis) and 810 days (heart failure). In conclusion, in selected patients with nonischemic dilated cardiomyopathy, a prolonged period of HVAD support in conjunction with heart failure medications can lead to recovery of left ventricular function. Surgical decommissioning is then an option to remove these patients from support. These patients are, however, not cured and remain at risk for future deterioration in ventricular function and infections.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAT.0000000000000523DOI Listing

Publication Analysis

Top Keywords

left ventricular
20
ventricular function
12
myocardial recovery
8
heartware left
8
ventricular assist
8
assist device
8
patients
8
recovery patients
8
nonischemic dilated
8
dilated cardiomyopathy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!