Generation of synthetic CT data using patient specific daily MR image data and image registration.

Phys Med Biol

Department of Radiation Oncology and Radiation Therapy, University of Heidelberg, Germany, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany. Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany.

Published: February 2017

To fully exploit the advantages of magnetic resonance imaging (MRI) for radiotherapy (RT) treatment planning, a method is required to overcome the problem of lacking electron density information. We aim to establish and evaluate a new method for computed tomography (CT) data generation based on MRI and image registration. The thereby generated CT data is used for dose accumulation. We developed a process flow based on an initial pair of rigidly co-registered CT and T2-weighted MR image representing the same anatomical situation. Deformable image registration using anatomical landmarks is performed between the initial MRI data and daily MR images. The resulting transformation is applied to the initial CT, thus fractional CT data is generated. Furthermore, the dose for a photon intensity modulated RT (IMRT) or intensity modulated proton therapy (IMPT) plan is calculated on the generated fractional CT and accumulated on the initial CT via inverse transformation. The method is evaluated by the use of phantom CT and MRI data. Quantitative validation is performed by evaluation of the mean absolute error (MAE) between the measured and the generated CT. The effect on dose accumulation is examined by means of dose-volume parameters. One patient case is presented to demonstrate the applicability of the method introduced here. Overall, CT data derivation lead to MAEs with a median of 37.0 HU ranging from 29.9 to 66.6 HU for all investigated tissues. The accuracy of image registration showed to be limited in the case of unexpected air cavities and at tissue boundaries. The comparisons of dose distributions based on measured and generated CT data agree well with the published literature. Differences in dose volume parameters kept within 1.6% and 3.2% for photon and proton RT, respectively. The method presented here is particularly suited for application in adaptive RT in current clinical routine, since only minor additional technical equipment is required.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/aa5200DOI Listing

Publication Analysis

Top Keywords

image registration
16
data
9
generated data
8
dose accumulation
8
mri data
8
generated dose
8
intensity modulated
8
measured generated
8
image
6
method
5

Similar Publications

Vertebral level in pregnancy according to the posterior superior iliac spine: an observational study.

BMC Pregnancy Childbirth

December 2024

Department of Anesthesiology, West China Second University Hospital, Sichuan University, 20#, Section 3 Renmin Nan Road, Chengdu, Sichuan, 610041, PR China.

Background: While the line joining the posterior superior iliac spine (PSIS) intersects a relatively stable sacral vertebra, it does not directly facilitate the localization of lumbar interspace or assist in the positioning for neuraxial anesthesia. Our study aimed to explore the potential of the PSIS line as a reference point and to determine its practical applicability in clinical settings.

Methods: We consecutively enrolled pregnant women with gestational ages ranging from 24 to 38 weeks scheduled for magnetic resonance imaging (MRI) examination.

View Article and Find Full Text PDF

Background: During the COVID-19 pandemia, the imaging test of choice to diagnose COVID-19 pneumonia as chest computed tomography (CT). However, access was limited in the hospital setting and patients treated in Primary Care (PC) could only access the chest x-ray as an imaging test. Several scientific articles that demonstrated the sensitivity of lung ultrasound, being superior to chest x-ray [Cleverley J et al.

View Article and Find Full Text PDF

Intensity-based 2D-3D registration methods are commonly used in musculoskeletal research and image-guided therapy to align 2D X-ray images with 3D CT scans. However, their success rate (SR) is limited by local optimization methods, which often cause the optimization of the underlying cost function to get stuck at a local minimum, resulting in false alignments. Global optimization methods aim to mitigate this problem, but despite their increasing popularity, the existing literature lacks consensus on which one is the most appropriate.

View Article and Find Full Text PDF

Background: Post-traumatic osteoarthritis (PTOA) often follows anterior cruciate ligament reconstruction (ACLR), leading to early cartilage degradation. Change in mean T fails to capture subject-specific spatial-temporal variations, highlighting the need for robust quantitative methods for early PTOA detection and monitoring.

Purpose/hypothesis: Develop and apply 3D T cluster analysis to ACLR and healthy knees over 2.

View Article and Find Full Text PDF

Purpose: In laparoscopic liver surgery, registering preoperative CT-extracted 3D models with intraoperative laparoscopic video reconstructions of the liver surface can help surgeons predict critical liver anatomy. However, the registration process is challenged by non-rigid deformation of the organ due to intraoperative pneumoperitoneum pressure, partial visibility of the liver surface, and surface reconstruction noise.

Methods: First, we learn point-by-point descriptors and encode location information to alleviate the limitations of descriptors in location perception.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!