Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Multifrequency capacitive micromachined ultrasound transducers (CMUTs) are introduced consisting of interlaced 82- [Formula: see text] (low frequency) and 36- [Formula: see text] (high frequency) membranes. The membranes have been interlaced on a scale smaller than the shortest wavelength of operation allowing several advantages over other multifrequency transducer designs including aligned beam profiles, optimal imaging resolution, and minimal grating lobes. The low- and high-frequency CMUTs operate at 1.74 and 5.04 MHz in immersion, respectively. Multifrequency transducers have applications in wideband photoacoustic (PA) imaging where multifrequency transducers are better able to detect both high- and low-frequency PA frequency content. The PA frequency content is target size dependent, which means traditional high-frequency transducers have less sensitivity to larger objects such as diffuse contrast agents. We demonstrate that the low-frequency subarrays are able to better visualize diffuse agent distributions, while the high-frequency subarrays offer fine-resolution imaging important for microvascular imaging and structural navigation. Spectroscopically unmixed images superimpose high sensitivity images of agent concentrations (acquired using low-frequency subarrays) onto high-resolution images of microvessel-mimicking phantoms (acquired using high-frequency subarrays).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2016.2620381 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!