We present an algorithm for fast continuous collision detection between points and signed distance fields, and demonstrate how to robustly use it for 6-DoF haptic rendering of contact between objects with complex geometry. Continuous collision detection is often needed in computer animation, haptics, and virtual reality applications, but has so far only been investigated for polygon (triangular) geometry representations. We demonstrate how to robustly and continuously detect intersections between points and level sets of the signed distance field. We suggest using an octree subdivision of the distance field for fast traversal of distance field cells. We also give a method to resolve continuous collisions between point clouds organized into a tree hierarchy and a signed distance field, enabling rendering of contact between rigid objects with complex geometry. We investigate and compare two 6-DoF haptic rendering methods now applicable to point-versus-distance field contact for the first time: continuous integration of penalty forces, and a constraint-based method. An experimental comparison to discrete collision detection demonstrates that the continuous method is more robust and can correctly resolve collisions even under high velocities and during complex contact.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TOH.2016.2613872DOI Listing

Publication Analysis

Top Keywords

collision detection
16
signed distance
16
distance field
16
6-dof haptic
12
haptic rendering
12
continuous collision
12
detection points
8
points signed
8
distance fields
8
demonstrate robustly
8

Similar Publications

Collision tumours: our recent experience.

Postepy Dermatol Alergol

December 2024

Department of Dermatology, Venereology and Allergology, Wroclaw Medical University, Wroclaw, Poland.

Introduction: Collision skin lesions (CSL) are rare clinical and pathological entities, posing significant diagnostic and therapeutic challenges. These lesions comprise at least two distinct cell populations - benign and/or malignant neoplasms - that are adjacent yet clearly demarcated. CSL were categorized as collision tumours into three types: two benign lesions, one benign and one malignant lesion, and two malignant lesions, with the most common being basal cell carcinoma (BCC) and melanocytic naevus.

View Article and Find Full Text PDF

IEEE 802.11 is one of the most common medium access control (MAC) protocols used in wireless networks. The carrier sense multiple access with collision avoidance (CSMA/CA) mechanisms in 802.

View Article and Find Full Text PDF

Joint communication and sensing (JCS) is becoming an important trend in 6G, owing to its efficient utilization of spectrums and hardware resources. Utilizing echoes of the same signal can achieve the object location sensing function, in addition to the V2X communication function. There is application potential for JCS systems in the fields of ADAS and unmanned autos.

View Article and Find Full Text PDF

Conjugation of short-chain fatty acids (SDFAs) to amines containing ring structures allows for better measurement by liquid chromatography tandem mass spectroscopy (LC-MS/MS). However, collision-induced dissociation (CID) results in breaking the conjugate back to the original SCFA and amine. We therefore set out to find an amine that would remain on the SCFA after CID and create a unique daughter for selectivity of measurement.

View Article and Find Full Text PDF

Enhanced Electrochemiluminescence from Ruthenium-Tagged Immune Complex at Flexible Chains for Sensitive Analysis of Glutamate Decarboxylase Antibody.

Biosensors (Basel)

January 2025

State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210092, China.

Herein, a sensitive electrochemiluminescence (ECL) immunosensor is designed by immobilizing ruthenium-tagged immune complexes at flexible poly-ethylene-glycol (PEG) chains on the electrode surface, which offers more freedom for the collision of the ruthenium complex at the electrode during the initial ECL reaction. The electrochemical characterizations confirm the loose structure of the assembled layer with the immune complex, providing an increase in the current and the resultant enhanced ECL emissions. Comparing the sensors with the rigid structure, a 34-fold increase in the maximal ECL emission is recorded when PEG3400 is used as a linker.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!