Study Design: Biomechanical investigation.
Purpose: Cervical two-level corpectomies with anterior-only instrumentation are associated with a high rate of implant-related complications. These procedures, therefore, often require an additional dorsal instrumentation to prevent screw loosening. Cement augmentation of the anterior screws in two-level corpectomies might stabilize the construct, so that a second dorsal procedure could be avoided. To evaluate the screw anchorage in cervical anterior-only procedures, an ex vivo evaluation of the range of motion (ROM) in two-level corpectomies (C4 and C5), with and without cement augmentation of the anterior screws, was carried out in this study.
Methods: Twelve human cervical cadaveric spines (C2-T1) were divided into two groups of six specimens each. Corpectomies were performed in C4 and C5, with grafting and anterior instrumentation with and without cement augmentation of the anterior screw-and-plate system (0.3-0.5 mL cement/screw). Flexibility tests with pure moments (1.5 Nm) were carried out before and after three cyclic loading periods of 5000 cycles with increasing eccentric forces (100, 200, and 300 N).
Results: After corpectomy and instrumentation, the control group and the augmented group showed a significant reduction in ROM in comparison with the native states with average ROMs of 49% (±17%) and 24% (±10%), respectively (P = 0.006). The ROM in the control group increased significantly in all motion directions in the course of cyclic loading and approached native values after the third cyclic loading period, with an overall ROM of 78% (±22%). In contrast, the augmented group maintained a significantly decreased ROM in all motion directions during cyclic loading, with a final ROM of 32% (±14%) after the third period of cyclic testing. Inter-group comparison demonstrated a significant difference between the two groups in the course of cyclic loading. The cement-augmented group outperformed the control group in all motion directions, with a significantly lower ROM after all three cyclic loading periods.
Conclusions: A two-level corpectomy with cement-augmentation results in a significantly reduced ROM. In comparison with the conventional anterior screw-and-plate fixation, it represents a significantly stabilized two-level anterior construct. This might be a treatment option for patients with a two-level corpectomy associated with reduced bone mineral density, to avoid an additional dorsal instrumentation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00586-017-4951-8 | DOI Listing |
J Shoulder Elbow Surg
January 2025
Division of Orthopaedic Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada. Electronic address:
Introduction: Primary glenohumeral arthritis is typically associated with glenoid retroversion and posterior bone loss. Glenoid component fixation remains a weak link in the survivorship of anatomical total shoulder arthroplasty, particularly in the B2 glenoid. The aim of this study was to compare biomechanical properties of two glenoid preparation techniques in a B2 glenoid bone loss model.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
N.N. Semenov Federal Research Center for Chemical Physics, Russian Academy of Sciences, 119991 Moscow, Russia.
In this work, the fracture mechanism of winding carbon-fiber-reinforced plastics (CFRPs) based on epoxy matrices reinforced by polysulfone film was investigated. Two types of polymer matrices were used: epoxy oligomer (EO) cured by iso-methyltetrahydrophthalic anhydride (iso-MTHPA), and EO-modified polysulfone (PSU) with active diluent furfuryl glycidyl ether (FGE) cured by iso-MTHPA. At the winding stage, the reinforcing film was placed in the middle layer of the CFRP.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
Department of Mechanical Engineering, Hanyang University, 222 Wangsimri-ro, Seongdong-gu, Seoul 04763, Republic of Korea.
This study presents a methodology for characterizing the constituent properties of composite materials by back-calculating from the laminate behavior under fatigue loading. Composite materials consist of fiber reinforcements and a polymer matrix, with the fatigue performance of the laminate governed by the interaction between these constituents. Due to the challenges in directly measuring the properties of individual fibers and the polymer matrix, a reverse-engineering approach was employed.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Department of Mechanical Engineering, École de Technologie Supérieure, 1100 Notre-Dame Ouest, Montreal, QC H3C 1K3, Canada.
Bolted joints, prevalent in industrial applications for component fastening, are susceptible to self-loosening-a critical issue resulting in a gradual reduction in clamping force. Gaining insight into the underlying mechanisms of self-loosening is crucial. While prior research has largely focused on evaluating component stiffness, limited attention has been given to its impact on the self-loosening behavior of bolted joints under transverse cyclic loading.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
School of Civil Engineering, Central South University, Changsha 410075, China.
Geopolymer, as a promising inorganic binding material, holds potential for use in constructing base layers for highway pavements. This study aims to evaluate the mechanical properties of geopolymer-stabilized macadam (GSM) at both the micro- and macro-scale by a series of tests, demonstrating that high-Ca GSM is a high-quality material for pavement base layers. The results demonstrated that GSM exhibits outstanding mechanical and fatigue properties, significantly surpassing those of cement-stabilized macadam (CSM).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!