Objective: The aim of this study was to compare the radiological and functional results of posterior cruciate ligament (PCL) - retaining and posterior-stabilized total knee arthroplasties in patients with severe varus gonarthrosis.

Methods: Medical records of 112 knees of 96 patients who underwent total knee arthroplasty for severe varus (≥15°) were reviewed. PCL-retaining and PCL-stabilizing groups consisted of 58 and 54 knees, respectively. Mean follow-up time was 56.6 months (range: 24-112 months). Knee Society (KS) clinical rating system was used in clinical evaluation. Range of motion, degree of flexion contracture, postoperative alignment, and complication rates were compared between the groups.

Results: Mean preoperative mechanical tibiofemoral angle was 20.1° in varus alignment, and was restored to 4.6° in valgus postoperatively. No statistically significant differences were found between PCL-stabilizing and PCL-retaining groups when KS knee scores, function scores, and flexion arc were evaluated. Two patients in PCL-retaining group underwent revision surgery due to aseptic loosening of tibial component. One patient in PCL-stabilizing group needed arthrotomy due to patellar clunk syndrome.

Conclusion: There were no notable differences between the 2 groups and PCL-retaining design had outcomes as good as PCL-stabilizing total knee implant in osteoarthritic knees with severe varus deformity.

Level Of Evidence: Level III, Therapeutic study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6197631PMC
http://dx.doi.org/10.1016/j.aott.2016.12.008DOI Listing

Publication Analysis

Top Keywords

total knee
16
severe varus
16
posterior-stabilized total
8
knee arthroplasty
8
knee
6
varus
5
posterior cruciate-retaining
4
cruciate-retaining versus
4
versus posterior-stabilized
4
total
4

Similar Publications

Background: Total Hip Arthroplasty (THA) is a transformative surgical intervention for hip joint disorders, necessitating meticulous preoperative planning for optimal outcomes. With the emergence of Artificial Intelligence (AI), preoperative planning paradigms have evolved, leveraging AI algorithms for enhanced decision support and imaging analysis. This systematic review aims to comprehensively evaluate the role of AI in THA preoperative planning, synthesizing evidence from studies exploring various AI techniques and their applications.

View Article and Find Full Text PDF

Background: Older adults and Hispanic individuals are increasingly turning to social media platforms to access health-related information. The purpose of this project was to evaluate a social media campaign to disseminate information from decision aids (DAs) on hip and knee osteoarthritis to Spanish-speaking adults.

Methods: A social media marketing team helped create an 8-mo campaign posted across 3 social media platforms to promote visits to a Web site offering free multilingual DAs for treatment of hip or knee osteoarthritis.

View Article and Find Full Text PDF

[Purpose] This study aimed to compare the effects of transcutaneous electrical nerve stimulation and microcurrent electrical neuromuscular stimulation on pain relief and knee function following total knee arthroplasty. [Participants and Methods] This was a prospective, single-center, three-group parallel study. Thirty-five patients scheduled for total knee arthroplasty were divided into transcutaneous electrical nerve stimulation, microcurrent electrical neuromuscular stimulation, and control groups.

View Article and Find Full Text PDF

Resilience to stressors has emerged as a major gerontological concept aiming to promote more positive outcomes for older adults. Achieving this aim relies on determining mechanisms underlying capacity to respond resiliently. This paper seeks proof of principle for the hypothesis that physical aspects of said capacity are rooted in the fitness of one's physiology governing stress response, conceptualized as a dynamical system.

View Article and Find Full Text PDF

Background: Contamination of sterilized surgical instruments is not a typically suspected source of increased infection rate, especially if no abnormalities in the sterilization process are detected.

Purpose/hypothesis: The purpose of this study was to report increased infection rates after knee ligament reconstructions due to undetectable sterilization process errors leading to residual moisture, not limited to a specific surgical tool. It was hypothesized that (1) residual moisture on surgical tools due to autoclave overloading would not be detected by autoclave self-diagnostics, chemical and biological tests, or organoleptic assessment and (2) this kind of contamination may elevate infection rates, especially in knee intra-articular reconstruction procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!