Current literature on pulmonary fibrosis induced in animal models highlights the need of an accurate, reliable and reproducible histological quantitative analysis. One of the major limits of histological scoring concerns the fact that it is observer-dependent and consequently subject to variability, which may preclude comparative studies between different laboratories. To achieve a reliable and observer-independent quantification of lung fibrosis we developed an automated software histological image analysis performed from digital image of entire lung sections. This automated analysis was compared to standard evaluation methods with regard to its validation as an end-point measure of fibrosis. Lung fibrosis was induced in mice by intratracheal administration of bleomycin (BLM) at 0.25, 0.5, 0.75 and 1 mg/kg. A detailed characterization of BLM-induced fibrosis was performed 14 days after BLM administration using lung function testing, micro-computed tomography and Ashcroft scoring analysis. Quantification of fibrosis by automated analysis was assessed based on pulmonary tissue density measured from thousands of micro-tiles processed from digital images of entire lung sections. Prior to analysis, large bronchi and vessels were manually excluded from the original images. Measurement of fibrosis has been expressed by two indexes: the mean pulmonary tissue density and the high pulmonary tissue density frequency. We showed that tissue density indexes gave access to a very accurate and reliable quantification of morphological changes induced by BLM even for the lowest concentration used (0.25 mg/kg). A reconstructed 2D-image of the entire lung section at high resolution (3.6 μm/pixel) has been performed from tissue density values allowing the visualization of their distribution throughout fibrotic and non-fibrotic regions. A significant correlation (p<0.0001) was found between automated analysis and the above standard evaluation methods. This correlation establishes automated analysis as a novel end-point measure of BLM-induced lung fibrosis in mice, which will be very valuable for future preclinical drug explorations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5249201 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0170561 | PLOS |
Clin Oral Investig
January 2025
Department of Behavioral and Community Dentistry, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, P.O. Box 450, Gothenburg, SE-40530, Sweden.
Objective: To investigate if changes in body mass index (BMI) result in changes of the mandibular trabecular bone structure.
Materials And Methods: Females (18-35 years at baseline, mean BMI 42,3) were followed from before (n = 117) until two years (n = 66) after obesity treatment (medical or surgical). The mandibular bone trabeculation was classified as sparse, dense, or mixed on intraoral radiographs (Lindh's index).
Int Immunopharmacol
January 2025
Division of Endocrinology, Tongji Hospital, Huazhong University of Science & Technology, Wuhan, 430030, PR China; Branch of National Clinical Research Center for Metabolic Diseases, Hubei, PR China. Electronic address:
Recent studies demonstrated that glucagon-like peptide-1 receptor agonists (GLP-1RA) have promising prospects in promoting wound healing. In this study, we intend to investigate the pro-healing effect and potential molecular mechanism of topical administration of GLP-1RA liraglutide on wounds in normoglycemic mice. Two full-thickness wounds were created on the back of the C57BL/6 mice.
View Article and Find Full Text PDFAppl Radiat Isot
January 2025
Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, China. Electronic address:
This study investigated the influence of tissue electron density on proton beam dose distribution using TOPAS Monte Carlo simulation. Heterogeneous tissue models composed of 14 materials were constructed to simulate the dose deposition process of a 169.23 MeV proton beam.
View Article and Find Full Text PDFJ Clin Densitom
December 2024
Service de Médecine Nucléaire, Hôpital Lapeyronie, CHU Montpellier, France; Physiologie et Médecine Expérimentale du Cœur et des Muscles (PhyMedEx), INSERM, CNRS, Université de Montpellier (UM), France.
Purpose: The aim of this study was to investigate the correlations between areal bone mineral density (aBMD) and body composition measured by two dual-energy X-ray absorptiometers (DXA), the DMS Stratos® (STR) and the Hologic Horizon A® (HRZ), and then generate cross-calibration equations between the two scanners.
Methods: Repeat scans were obtained from 251 adults (85 % female), 36 ± 14 years old with mean body mass index (BMI) of 28.7 ± 11.
Eur Radiol
January 2025
Department of Information Technology, Uppsala University, 75237, Uppsala, Sweden.
Objectives: The aim is to assess the feasibility and accuracy of a novel quantitative ultrasound (US) method based on global speed-of-sound (g-SoS) measurement using conventional US machines, for breast density assessment in comparison to mammographic ACR (m-ACR) categories.
Materials And Methods: In a prospective study, g-SoS was assessed in the upper-outer breast quadrant of 100 women, with 92 of them also having m-ACR assessed by two radiologists across the entire breast. For g-SoS, ultrasonic waves were transmitted from varying transducer locations and the image misalignments between these were then related analytically to breast SoS.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!