A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Non-invasive blood glucose detection system based on conservation of energy method. | LitMetric

AI Article Synopsis

  • The text discusses a new method to monitor blood glucose (BG) levels non-invasively, using a mixed signal processor (MSP430) microcontroller to reduce the risks associated with traditional glucose testing methods.
  • It mentions the system's reliance on various physiological parameters such as blood oxygen saturation, heart rate, and blood flow, along with a novel algorithm (DCBPN) that combines decision tree and neural network approaches for accurate predictions.
  • The results from 400 clinical trials show that this non-invasive BG detection system can achieve an accuracy of 88.53%, indicating its potential for reliable use among diabetic patients and other individuals.

Article Abstract

The most common method used for minimizing the occurrence of diabetes complications is frequent glucose testing to adjust the insulin dose. However, using blood glucose (BG) meters presents a risk of infection. It is of great importance to develop non-invasive BG detection techniques. To realize high-accuracy, low-cost and continuous glucose monitoring, we have developed a non-invasive BG detection system using a mixed signal processor 430 (MSP430) microcontroller. This method is based on the combination of the conservation-of-energy method with a sensor integration module, which collects physiological parameters, such as the blood oxygen saturation (SPO), blood flow velocity and heart rate. New methods to detect the basal metabolic rate (BMR) and BV are proposed, which combine the human body heat balance and characteristic signals of photoplethysmography as well dual elastic chambers theory. Four hundred clinical trials on real-time non-invasive BG monitoring under suitable experiment conditions were performed on different individuals, including diabetic patients, senior citizens and healthy adults. A multisensory information fusion model was applied to process these samples. The algorithm (we defined it as DCBPN algorithm) applied in the model combines a decision tree and back propagation neural network, which classifies the physiological and environmental parameters into three categories, and then establishes a corresponding prediction model for the three categories. The DCBPN algorithm provides an accuracy of 88.53% in predicting the BG of new samples. Thus, this system demonstrates a great potential to reliably detect BG values in a non-invasive setting.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6579/aa50cfDOI Listing

Publication Analysis

Top Keywords

blood glucose
8
detection system
8
non-invasive detection
8
dcbpn algorithm
8
three categories
8
non-invasive
5
non-invasive blood
4
glucose
4
glucose detection
4
system based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!