Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Reliable quantitative measurements of HE4 and CA125 levels are required to calculate the risk of ovarian malignancy algorithm (ROMA) value. We suggest a new reporting strategy for interpreting ROMA values based on analytical measurement range (AMR) and qualified-intervals of the HE4 and CA125 results.
Methods: HE4 and CA125 assays from Abbott and Roche were used. The AMRs and the qualified-intervals were as follows: Architect HE4 assay, 20-1500 and 17.2-2637.8 pmol/L; Architect CA125 II assay, 1-1000 and 3.9-14,163.0 U/mL; Elecsys HE4 assay, 15-1500 and 28.8-3847 pmol/L; Elecsys CA125 II assay, 0.6-5000 and 6.5-5000 U/mL. These values were used to simulate the ROMA values.
Results: Reporting algorithm for the ROMA value could be classified into three categories. (1) If quantitative HE4 and CA125 levels are reliable, the numerical ROMA value can be reported. (2) If HE4 value is <20 and <28.8 for Abbott and Roche in premenopausal woman, the ROMA value should be reported as "low risk" regardless of the CA125 result. In postmenopausal woman, however, it should be reported as "low risk" (CA125<203.0 and <165.8 for Abbott and Roche) or "undetermined" (vice-versa value). (3) If CA125 value is <3.9 and <6.5 for Abbott and Roche, it should be reported as "low risk" (premenopausal HE4<51.5 and <62.2, postmenopausal HE4<323.0 and <281.5 for Abbott and Roche) or "undetermined" (vice-versa value).
Conclusions: New reporting strategy will provide more informative reporting of ROMA values in clinical practice.