Objective: Among primary prevention patients with heart failure receiving cardiac resynchronisation therapy (CRT), the impact of additional implantable cardioverter defibrillator (ICD) treatment on outcomes and its interaction with sex remains uncertain. We aim to assess whether the addition of the ICD functionality to CRT devices offers a more pronounced survival benefit in men compared with women, as previous research has suggested.
Methods: Observational multicentre cohort study of 5307 consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy and no history of sustained ventricular arrhythmias having CRT implantation with (cardiac resynchronisation therapy defibrillator (CRT-D), n=4037) or without (cardiac resynchronisation therapy pacemaker (CRT-P), n=1270) defibrillator functionality. Using propensity score (PS) matching and weighting and cause-of-death data, we assessed and compared the outcome of patients with CRT-D versus CRT-P. This analysis was stratified according to sex.
Results: After a median follow-up of 34 months (interquartile range 22-60 months) no survival advantage, of CRT-D versus CRT-P was observed in both men and women after PS matching (HR=0.95, 95% CI 0.77 to 1.16, p=0.61, and HR=1.30, 95% CI 0.83 to 2.04, p=0.25, respectively). With inverse-probability weighting, a benefit of CRT-D was seen in male patients (HR 0.78, 95% CI 0.65 to 0.94, p=0.012) but not in women (HR 0.87, 95% CI 0.63 to 1.19, p=0.43). The excess unadjusted mortality of patients with CRT-P compared with CRT-D was related to sudden cardiac death in 7.4% of cases in men but only 2.2% in women.
Conclusions: In primary prevention patients with CRT indication, the addition of a defibrillator might convey additional benefit only in well-selected male patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/heartjnl-2016-310677 | DOI Listing |
Front Cardiovasc Med
January 2025
Department of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.
Aims: This retrospective cohort study aimed to investigate the efficacy of dual-chamber left Bundle branch pacing (LBBP) as an alternative therapy for heart failure patients with complete left bundle branch block (CLBBB) and indications for defibrillator with cardiac resynchronization therapy (CRT-D).
Methods: 34 patients met inclusion criteria were enrolled in the study. These criteria included a left ventricular ejection fraction (LVEF) of lower than 35%, a New York Heart Association functional class of II-IV, CLBBB meeting Strauss's criteria, intraventricular dyssynchrony, and confirmed correction of CLBBB during LBBP.
Eur Heart J Case Rep
January 2025
Department of Cardiology, Yokohama City University Hospital, 3-9 Fukuura, Kanazawa-Ku, Yokohama city, Kanagawa 236-0004, Japan.
Background: Coronary sinus (CS) lead placement in persistent left superior vena cava (PLSVC) cases is challenging because of the poor backup force of the guiding catheter within the enlarged CS. Active fixation Quadripolar leads (Attain Stability™ Quad 4798, Medtronic) can expand choice to CS branches with limited access; however, no cases of anchoring to the main body of the CS have been published to date.
Case Summary: We describe a case of cardiac resynchronization therapy pacemaker upgrade in a 79-year-old female who developed pacing-induced cardiomyopathy after pacemaker implantation via the right superior vena cava (SVC) for atrioventricular block eight years ago wherein PLSVC was revealed during the procedure.
Handb Clin Neurol
January 2025
Department of Surgical Medical and Molecular Pathology and Critical Care Medicine, University of Pisa, Pisa, Italy; Department of Neuroscience, Psychology Unit, University of Pisa Azienda Ospedaliera Universitaria Pisana (AUOP), Pisa, Italy.
Insomnia disorder is a frequent sleep disorder leading to significant health and economic consequences. It has been proposed that individuals with insomnia may experience compromised deactivation systems of arousal, leading to a chronic state of hyperactivation of arousal known as hyperarousal, along with instability in the flip-flop system. Such disruptions may have a primarily impact on the sleep homeostatic drive process.
View Article and Find Full Text PDFJ Electrocardiol
January 2025
Victorian Heart Institute, Monash University, Clayton, VIC, Australia; Victorian Heart Hospital, Clayton, VIC, Australia. Electronic address:
Introduction: This study evaluates various formulae used to correct the QT interval in patients with wide QRS complexes to calculate corrected QT (QTc) following Cardiac Resynchronisation Therapy (CRT).
Methods: We included patients with severe heart failure and left bundle branch block, presenting with a QRS duration of at least 120 milliseconds, who underwent successful CRT implantation. Patients were excluded if they had non-lateral left ventricular lead placement, metabolic disorders, atrial fibrillation, atrial tachycardia, or high-degree atrioventricular block prior to implantation.
Micromachines (Basel)
January 2025
Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.
Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.