Background: Student training in use of automated external defibrillators and deployment of such defibrillators in schools is recommended to increase survival after out-of-hospital cardiac arrest. Low implementation rates have been observed, and even at schools with a defibrillator, challenges such as delayed access have been reported. The purpose of this study was to identify barriers to the implementation of defibrillator training of students and deployment of defibrillators in schools.
Methods: A qualitative study based on semi-structured individual interviews and focus groups with a total of 25 participants, nine school leaders, and 16 teachers at eight different secondary schools in Denmark (2012-2013). Thematic analysis was used to identify regular patterns of meaning using the technology acceptance model and focusing on the concepts of perceived usefulness and perceived ease of use.
Results: School leaders and teachers are concerned that automated external defibrillators are potentially dangerous, overly technical, and difficult to use, which was related to their limited familiarity with them. They were ambiguous about whether or not students are the right target group or which grade is suitable for defibrillator training. They were also ambiguous about deployment of defibrillators at schools. Those only accounting for the risk of students, considering their schools to be small, and that time for professional help was limited, found the relevance to be low. Due to safety concerns, some recommended that defibrillators at schools should be inaccessible to students. They lacked knowledge about how they work and are operated, and about the defibrillators already placed at their campuses (e.g., how to access them). Prior training and even a little knowledge about defibrillators were crucial to their perception of student training but not for their considerations on the relevance of their placement at schools.
Conclusions: It is crucial for implementation of automated external defibrillators in schools to inform staff about how they work and are operated and that students are an appropriate target group for defibrillator training. Furthermore, it is important to provide schools with a basis for decision making about when to install defibrillators, and to ensure that school staff and students are informed about their placement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5248449 | PMC |
http://dx.doi.org/10.1186/s12873-017-0114-9 | DOI Listing |
Circ Cardiovasc Qual Outcomes
January 2025
Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas (S.G., Nimesh Patel, M.K., M.S.S.).
JACC Adv
December 2024
Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA.
Background: Risk stratification for sudden cardiac death (SCD) in patients with nonischemic cardiomyopathy (NICM) remains challenging.
Objectives: This study aimed to investigate the impact of epicardial adipose tissue (EAT) on SCD in NICM patients.
Methods: Our study cohort included 173 consecutive patients (age 53 ± 14 years, 73% men) scheduled for primary prevention implantable cardioverter-defibrillators (ICDs) implantation who underwent preimplant cardiovascular magnetic resonance.
JACC Adv
December 2024
Division of Cardiology, The Johns Hopkins Hospital, Baltimore, Maryland, USA.
This state-of-the-art review examines disparities in the diagnosis, management, and outcomes of cardiac arrhythmias globally. These arrhythmias include atrial fibrillation, ventricular tachyarrhythmias underlying sudden cardiac death, and bradyarrhythmias associated with sinus node and atrioventricular node disease. Arrhythmias in low- and middle-income countries often result in higher mortality rates due to complex and poorly documented risk factors, lack of clinical expertise among health care personnel, lack of sufficient infrastructure, and challenges in access to care.
View Article and Find Full Text PDFJ Arrhythm
February 2025
Current guidelines recommend cardioverter-defibrillator (ICD) programming, including faster detection rates, longer detection durations, and strict discrimination for supraventricular tachycardia (SVT) to prevent unnecessary ICD treatment. This delayed-style ICD programming could lead to a rise in the possibility of VF undersensing. To avoid this risk, an innovative algorithm known as VF Therapy Assurance (VFTA; Abbott, Sylmar, CA) has been developed.
View Article and Find Full Text PDFBackground: The most effective way to treat patients following a first ICD therapy is unclear. We hypothesised that following first ICD therapy, combining different treatment strategies would be associated with a reduction in the risk of subsequent therapy compared to single strategies alone.
Methods: Data was collected from consecutive patients undergoing ICD implantation at King's College Hospital between January 2009 and December 2019.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!