Embryonic stem cells (ESCs) are an ideal source for chondrogenic progenitors for the repair of damaged cartilage tissue. It is currently difficult to induce uniform and scalable ESC differentiation in vitro, a process required for stem cell therapy. This is partly because stem cell fate is determined by complex interactions with the native microenvironment and mechanical properties of the extracellular matrix. Mechanical signaling is considered to be one of the major factors regulating the proliferation and differentiation of chondrogenic cells both in vitro and in vivo. We used biocompatible and elastic polydimethylsiloxane (PDMS) scaffolds, capable of transducing mechanical signals, including compressive stress in vitro. ESCs seeded into the PDMS scaffolds and subjected to mechanical loading resulted in induction of differentiation. Differentiated ESC derivatives in three-dimensional (3-D) PDMS scaffolds exhibited elongated single cell rather than round clonal ESC morphology. They expressed chondrogenic marker, Col2, with concomitant reduction in the expression of pluripotent marker, Oct4. Immunocytochemical analysis also showed that the expression of COL2 protein was significantly higher in ESCs in 3-D scaffolds subjected to compressive stress. Further analysis showed that compressive stress also resulted in expression of early chondrogenic makers, Sox9 and Acan, but not hypertrophic chondrogenic markers, Runx2, Col10, and Mmp13. Compressive stress induced differentiation caused a reduction in the expression of β-Catenin and an increase in the expression of genes, Rhoa, Yap, and Taz, which are known to be affected by mechanosignaling. The chondroinductive role of RhoA was confirmed by its downregulation with simultaneous decrease in the transcriptional and translational expression of early chondrogenic markers, SOX9, COL2, and ACAN, when ESCs in PDMS scaffolds were subjected to compressive stress and treated with RhoA inhibitor, CCG-1432. Based on these observations, a model for compression induced chondrogenic differentiation of ESCs in 3-D scaffolds was proposed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/ten.TEA.2016.0376 | DOI Listing |
J Mol Model
January 2025
Department of Mechanical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, 807, Taiwan.
Context: To address the severe fuel crisis and environmental pollution, the use of lightweight metal materials, such as AZ alloy, represents an optimal solution. This study investigates the mechanical behavior and deformation mechanism of AZ alloys under uniaxial compressive using molecular dynamics (MD) simulations. The influence of various compositions, grain sizes (GSs), and temperatures on the compressive stress, the ultimate compressive strength (UCS), compressive yield stress (CYS), Young's modulus (E), shear strain, phase transformation, dislocation distribution, and total deformation length is thoroughly examined.
View Article and Find Full Text PDFBackground: To compare the effect of minimally invasive and open transforaminal lumbar interbody fusion (TLIF) approaches in fusing the L4-L5 segment and predicting the potential risk of adjacent segment degeneration (ASD).
Methods: A computed tomography scan image was processed and the three-dimensional model of the L1-L5 spine was reconstructed. The minimally invasive and Open TLIF finite element models were constructed.
Clin Biomech (Bristol)
January 2025
Department of Kinesiology and Physical Education, Wilfrid Laurier University, Waterloo, Ontario, Canada; Department of Health Sciences, Wilfrid Laurier University, Waterloo, Ontario, Canada. Electronic address:
Background: Fusion changes the biomechanics of the spine leading to the potential development of adjacent segment disease. Despite many studies on adjacent segment disease, it is largely unknown how spinal fixation affects the mechanical properties of the adjacent disc. The purpose of this study was to assess whether axial compression causes mechanical disruption to the annulus when the caudal spinal level is immobilized or injured.
View Article and Find Full Text PDFObjectives: To analyse and compare the functionality of extraluminal and intraluminal artificial urinary sphincters (AUSs), an in silico procedure has been defined and applied. Design and reliability assessments of the AUS are typically performed using a clinical approach, which does not provide data on mechanical stimulation of urethral tissues. Mechanical stimulation may determine tissue degeneration, such as urethral atrophy or erosion, the main causes of AUS failure.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha, 410004, China.
3D porous carbon electrodes have attracted significant attention for advancing compressible supercapacitors (SCs) in flexible electronics. The micro- and nanoscale architecture critically influences the mechanical and electrochemical performance of these electrodes. However, achieving a balance between high compressive strength, electrochemical stability, and cost-effective sustainable production remains challenging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!