Low-cost hand-held probe for depth-resolved low-coherence interferometry.

Biomed Opt Express

Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA; Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA; Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA; Department of Internal Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.

Published: January 2017

We report on the development of a low-cost hand-held low-coherence interferometric imaging system based on the principle of linear optical coherence tomography (Linear OCT), a technique which was first proposed in the early 2000s as a simpler alternative to the conventional time-domain and Fourier-domain OCT. A bench-top implementation of the proposed technique is first presented and validated. The axial resolution, SNR, and sensitivity roll-of of the system was estimated to be 5.2 m and 80 dB, and 3.7 dB over a depth of 0.15 mm, respectively. After validating the bench-top system, two hand-held probe implementations for contact-based imaging and human tympanic membrane imaging are presented. The performance of the proposed system was compared with a research-grade state-of-the-art Fourier-domain low coherence interferometry (LCI) system by imaging several biological and non-biological samples. The results of this study suggest that the proposed system might be a suitable choice for applications where imaging depth and SNR can be traded for lower cost and simpler optical design.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5231303PMC
http://dx.doi.org/10.1364/BOE.8.000338DOI Listing

Publication Analysis

Top Keywords

low-cost hand-held
8
hand-held probe
8
proposed system
8
system
6
imaging
5
probe depth-resolved
4
depth-resolved low-coherence
4
low-coherence interferometry
4
interferometry report
4
report development
4

Similar Publications

Development of an accurate synchronous transport signal hand-held sensing platform for fluorescence-based berberine on-site detection.

Anal Chim Acta

December 2024

School of Chemistry and Chemical Engineering, Henan Normal University, Collaborative Innovation Center of Henan Province for Green Manufacturing of Fine Chemicals, Key Laboratory of Green Chemical Media and Reactions, Ministry of Education, National Demonstration Center for Experimental Chemistry Education, Xinxiang, Henan, 453007, China. Electronic address:

Background: Berberine is widely used in clinical treatment because of its wide antibacterial spectrum and low toxic side effects. However, its abuse could lead to bacterial resistance and several other adverse effects. In addition, measuring the content of berberine in environmental water samples helps to monitor its accumulation and metabolism in ecosystems.

View Article and Find Full Text PDF

Visible diffuse reflectance smartphone spectrometer with high spectral accuracy.

Spectrochim Acta A Mol Biomol Spectrosc

February 2025

Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh. Electronic address:

Article Synopsis
  • A smartphone-based spectrometer is designed for analyzing solid samples using diffuse reflection, featuring a thin-film grating and a diffuse surface to capture light.
  • The device simplifies optical setup by directly using a smartphone's CMOS camera to capture light without needing complex optics, achieving a maximum wavelength resolution of 0.08 nm/pixel within a spectrum of 400-700 nm.
  • It successfully identifies food color pigments and detects possible food adulteration, offering a compact, affordable (around $50), and portable solution for on-site testing.
View Article and Find Full Text PDF

Flow assurance is a long-term challenge for oil and gas exploration as it plays a key role in designing safe and efficient operation techniques to ensure the uninterrupted transport of reservoir fluids. In this regard, the sensitive monitoring of the scale formation process is important by providing an accurate assessment of the minimum inhibitor concentration (MIC) of antiscale products. The optimum dosage of antiscale inputs is of pivotal relevance as their application at concentrations both lower and higher than MIC can imply pipeline blockages, critically hindering the entire supply chain of oil-related inputs and products to society.

View Article and Find Full Text PDF

Three-dimensional (3D) printing is an emerging technology to develop devices on a large scale with potential application for electroanalysis. However, 3D-printed electrodes, in their native form, provide poor electrochemical response due to the presence of a high percentage of thermoplastic polymer in the conductive filaments. Therefore, surface treatments are usually required to remove the nonconductive material from the 3D-printed electrode surfaces, providing a dramatic improvement in the electroanalytical performance.

View Article and Find Full Text PDF

Foot-and-mouth disease (FMD) is a highly contagious viral disease of cloven-hoofed animals responsible for economic losses that amount to >$20 billion annually. Rapid recognition of FMD cases provides vital information to guide control programmes. A range of point-of-need amplification technologies have been developed which allow sensitive detection of the causative virus (FMDV) in the field at locations remote from laboratories.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!