Objectives: Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and valve-in-valve (ViV) procedures has been increasingly recognized. However, the factors affecting the post-TAVR/ViV thrombosis are not fully understood. This study aimed to investigate the effect of the geometric confinement of transcatheter aortic valve (TAV) on blood residence time (BRT) on the TAV leaflets and in turn on the post-TAVR valve thrombosis.
Methods: Two computational models, representing a surgical bioprosthesis and a TAV, were developed to study the effect of the geometric confinement on BRT on the leaflets in ViV setting/TAVR Intra-annular positioning. 3D flow fields were obtained via a one-way fluid-solid interaction modelling approach validated by experimental testing. BRT was compared between the two models by quantification and statistical analysis of the residence time of randomly distributed particles in close proximity of the leaflets.
Results: Significantly longer BRT on the leaflets was observed in the TAV compared to the surgical valve during different stages of the cardiac cycle. During forward flow, the mean value of BRT was found to be 39% higher in the TAV compared to the surgical bioprosthesis ( P < 0.0001). During diastole, specifically from end-systole to mid-diastole and from mid-diastole to the beginning of systole, the amount by which the mean BRT was higher for TAV compared to the surgical valve was 150% and 40%, respectively ( P < 0.0005).
Conclusions: The geometric confinement of TAV by the failed bioprosthesis or the calcified native valve increases the BRT on the TAV leaflets. This may act as a permissive factor in valve thrombosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/ejcts/ezw407 | DOI Listing |
Cardiovasc Revasc Med
December 2024
Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:
Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
November 2024
Department of Cardiovascular Medicine, Mayo Clinic, Phoenix, AZ 85054, USA.
Bioprosthetic aortic valve degeneration (BAVD) is a significant clinical concern following both transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). The increasing use of bioprosthetic valves in aortic valve replacement in younger patients and the subsequent rise in cases of BAVD are acknowledged in this review which aims to provide a comprehensive overview of the incidence, diagnosis, predictors, and management of BAVD. Based on a thorough review of the existing literature, this article provides an updated overview of the biological mechanisms underlying valve degeneration, including calcification, structural deterioration, and inflammatory processes and addresses the various risk factors contributing to BAVD, such as patient demographics, comorbidities, and procedural variables.
View Article and Find Full Text PDFJ Pers Med
November 2024
Department of Pulmonary and Critical Care Medicine, The University of Toledo, Toledo, OH 43606, USA.
Aortic stenosis (AS) is a critical valvular heart disease associated with significant morbidity and mortality if not managed promptly. Previous studies have highlighted the "weekend effect", where the day of admission impacts outcomes in various cardiac conditions. This study evaluates the impact of weekend versus weekday admissions on outcomes in patients admitted with acutely decompensated aortic stenosis.
View Article and Find Full Text PDFJ Surg Res
December 2024
Division of Cardiac Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio. Electronic address:
Introduction: Transcatheter aortic valve replacement (TAVR) has become a viable alternative to surgical aortic valve replacement (SAVR) for high-risk patients with aortic stenosis. One such high-risk group is patients with pulmonary hypertension (PH), which is known to increase surgical risk and adversely affect outcomes. This study aims to compare midterm and long-term survival in TAVR and SAVR among patients with PH.
View Article and Find Full Text PDFRev Esp Cardiol (Engl Ed)
December 2024
Département de Cardiologie, Institut universitaire de cardiologie et de pneumologie de Québec, Université Laval, Quebec, Canada. Electronic address:
Introduction And Objectives: The Valve Academic Research Consortium (VARC)-3 definition of the early safety (ES) composite endpoint after transcatheter aortic valve replacement (TAVR) lacks clinical validation. The aim of this study was to determine the incidence, predictors, and clinical impact of ES after TAVR as defined by VARC-3 criteria.
Methods: We performed a multicenter study including 10 078 patients with severe aortic stenosis undergoing transarterial TAVR.