A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simplified quantitative determination of phospholipids in amniotic fluid, alveolar lavages and milk using high performance liquid chromatography (HPLC). | LitMetric

A one step HPLC method for the determination of the main phospholipids, phosphatidylglycerol (PG), phosphatidylinositol (PI), phosphatidylethanolamine (PE), phosphatidylcholine (PC), sphingomyelin (SP) and lysolecithin (LL) in amniotic fluid, milk, tracheal secretion, lung lavages, gastric aspirates, infant formulas and some other human and animal media has been developed. Quantitation occurs automatically using computer calculation and lysolecithin as an internal standard. Detection limits are at about 0.2 micrograms/100 ml but may rise to about 0.3 micrograms/100 ml in cases of high fat levels or other interfering compounds. Recovery rates measured in amniotic fluid fluctuate around the 100% level. Time required for a single analysing including a blank run and a calibration standard solution measurement amounts to about two hours. In series analysis 12 samples per day can be examined, while the required time per sample is reduced to 40 minutes. As phospholipids carry an important function in many spheres of medicine, the improvement in specific quantitative determination of these compounds is of great importance.

Download full-text PDF

Source
http://dx.doi.org/10.1515/jpme.1989.17.3.203DOI Listing

Publication Analysis

Top Keywords

amniotic fluid
12
quantitative determination
8
simplified quantitative
4
determination phospholipids
4
phospholipids amniotic
4
fluid alveolar
4
alveolar lavages
4
lavages milk
4
milk high
4
high performance
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!