Plate Fixation Compared with Nonoperative Treatment for Displaced Midshaft Clavicular Fractures: A Multicenter Randomized Controlled Trial.

J Bone Joint Surg Am

1Leiden University Medical Center, Leiden, the Netherlands 2Flevo Hospital, Almere, the Netherlands 3Koningin Beatrix Hospital, Winterswijk, the Netherlands 4Maasstad Hospital, Rotterdam, the Netherlands 5IJsselland Hospital, Capelle a/d IJssel, the Netherlands 6Radboud University Medical Center, Nijmegen, the Netherlands.

Published: January 2017

Background: The use of operative treatment for clavicular fractures is increasing, despite varying results in previous studies. The aim of this study was to compare plate fixation and nonoperative treatment for displaced midshaft clavicular fractures with respect to nonunion, adverse events, and shoulder function.

Methods: In this multicenter, prospective, randomized controlled trial, patients between 18 and 60 years old with a displaced midshaft clavicular fracture were randomized between nonoperative treatment and open reduction with internal plate fixation. The primary outcome was evidence of nonunion at 1 year. Other outcomes were secondary operations, arm function as measured with the Constant shoulder score and Disabilities of the Arm, Shoulder and Hand (DASH) score, pain, cosmetic results, and general health status. Outcomes were recorded at 6 weeks, 3 months, and 1 year following trauma.

Results: One hundred and sixty patients were randomized. The rate of nonunion was significantly higher in the nonoperatively treated group than in the operatively treated group (23.1% compared with 2.4%; p < 0.0001), as was the rate of nonunion for which secondary plate fixation was performed (12.9% compared with 1.2%; p = 0.006). The rate of secondary operations was 27.4% in the operatively treated group (16.7% for elective plate removal) and 17.1% in the nonoperatively treated group (p = 0.18). Nineteen percent of the patients in the operatively treated group had persistent loss of sensation around the scar. No difference was found between the groups with respect to the Constant and DASH scores at all time points.

Conclusions: For patients with a diaphyseal fracture of the clavicle displaced at least 1 shaft width, plate fixation improves the chances that the bone will heal; however, the rate of patients who need a second operation is considerable. In addition, the procedure does not improve shoulder function or general symptoms, and it does not decrease limitations compared with nonoperative treatment in a sling.

Level Of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.15.01394DOI Listing

Publication Analysis

Top Keywords

plate fixation
20
treated group
20
nonoperative treatment
16
displaced midshaft
12
midshaft clavicular
12
clavicular fractures
12
operatively treated
12
compared nonoperative
8
treatment displaced
8
randomized controlled
8

Similar Publications

Purpose: Trauma and orthopaedic (T&O) surgery relies on medical implants and materials, often resulting in metalwork wastage (prosthesis, screws, nails, and plates). This places an economic strain on healthcare services and the environment. Our primary outcome is to quantify the implant wastage across the literature, and secondarily investigate the associated costs in this specialty.

View Article and Find Full Text PDF

Comparative finite element analysis: internal fixation plate versus intramedullary nail for neer type III-VI proximal humeral fractur.

J Orthop Surg Res

January 2025

Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing, 100020, China.

Background: Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.

Methods: Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.

View Article and Find Full Text PDF
Article Synopsis
  • Clavicle fractures are common in emergency departments, while acromioclavicular (AC) joint injuries are rare and even more so when combined with clavicle fractures.
  • A 29-year-old male patient experienced both an AC joint dislocation and a midshaft clavicle fracture, leading to surgical treatment that resulted in excellent recovery and range of motion after one year.
  • The case highlights the rarity of this combination of injuries and stresses the importance of timely diagnosis and investigation to achieve favorable functional outcomes, although there's still no agreement on the best treatment approach.
View Article and Find Full Text PDF

Background: Cervical spine pyogenic infection (CSPI) is a rare and challenging form of spinal infection that is typically caused by pyogenic bacteria and primarily affects the cervical vertebral bodies and surrounding tissues. Given its nonspecific symptoms, such as fever and neck pain, early diagnosis is crucial to prevent severe complications, including spinal cord injury. We report a previously unreported case of acute CSPI arising from chronic paronychia, exploring its diagnostic and therapeutic challenges through a review of the current literature.

View Article and Find Full Text PDF

Risk factors for complications following volar locking plate fixation of distal radial fractures.

Orthop Traumatol Surg Res

December 2024

Service de Chirurgie Orthopédique et Traumatologique, Hôpital de la Cavale Blanche, Boulevard Tanguy Prigent, Brest 29200, France; Université de Bretagne Occidentale, UBO, Brest 29200, France; LaTIM, INSERM, UMR 1101, SFR IBSAM, Avenue Foch, Brest 29200, France. Electronic address:

Article Synopsis
  • The study focuses on distal radial fractures and the complications associated with volar locking plate (VLP) fixation, which can lead to implant removal.
  • Researchers analyzed data from 2951 patients, identifying intrinsic (like age and fracture type) and extrinsic (such as plate positioning) risk factors for complications post-fixation.
  • Key findings revealed that being under 62 years old, having a specific type of fracture, and the plate's positioning were significant risk factors for complications that might necessitate implant removal.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!