Purpose: To evaluate the inter-relationship of soft contact lens base curve radius (BC), diameter, and lens fit using a mathematical model.
Methods: A spreadsheet mathematical model was used to evaluate theoretical fitting characteristics for various combinations of soft lens BC and diameter. The designs were evaluated using ocular topography data collected from 163 UK subjects. The model evaluated lens tightness (edge strain) and on-eye diameter (horizontal corneal overlap) and assumed that acceptable values fell within the range 0 to 6% and 0.2 to 1.2 mm, respectively. Analyses were undertaken of various trends relating to soft lens fit, including (1) the effect of BC and diameter on fitting success; (2) the effect of lens asphericity, BC, and sag on lens diameter on the eye; and (3) the effect of lens diameter on lens tightness.
Results: The highest overall success rate (90.2%) was achieved with an 8.60/14.2 mm (BC/diameter) design. Using this design on the sample population, the median edge strain value was 3.2% (IQR: 2.1%) whereas median corneal overlap was 0.62 mm (IQR: 0.35). There was a positive correlation (r = 0.37, P < .0001) between edge strain and corneal overlap. Edge strain showed significant correlations with each of the ocular topography variables, most notably corneal asphericity (-0.62, P < .0001). Corneal overlap showed significant correlations with corneal asphericity (r = -0.42, P < .0001) and corneal diameter (r = 0.92, P < .0001). For a 0.4 mm change in BC, it is necessary to change diameter by 0.2 mm to maintain similar on-eye diameter (arclength). When changing lens diameter, a change in BC of 0.2 mm is required to maintain similar tightness of fit.
Conclusions: Mathematical modeling is a useful technique for large-scale evaluation of the interactions of soft contact lens design and fit. The study has given useful insights into the general performance of soft lens designs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/OPX.0000000000001048 | DOI Listing |
Clin Exp Optom
January 2025
Department of Ophthalmology, Gaziantep City Hospital, Gaziantep, Turkey.
Clinical Relevance: Although laser refractive surgeries and multifocal intraocular lens implantation are generally avoided in patients with diabetic retinopathy, a substantial proportion of well-glycaemic-controlled type 2 diabetes mellitus patients are considered for these procedures. Pupil dynamics play a significant role in determining postoperative satisfaction in these patients.
Background: To evaluate pupillary dynamics in patients with and without diabetes following uneventful phacoemulsification surgery.
Invest Ophthalmol Vis Sci
January 2025
Laboratorio de Óptica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain.
Purpose: Peripheral optics have been suggested to play a role in myopia progression, with accommodation responses also considered a potential contributor. This study aimed to investigate whether modifications in peripheral optics through different spectacle lenses affect accommodation responses.
Methods: Dynamic accommodation responses were assessed using a double-pass instrument while switching the target from distance (3 m for 3 seconds) to near (0.
J Cataract Refract Surg
January 2025
Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK.
Purpose: To measure visual acuity at three different defocus planes in pseudophakic subjects with varying levels of spherical aberration induced by an adaptive optics visual simulator. The study aimed to simulate Extended Depth of Focus (EDOF) intraocular lenses (IOLs).
Setting: Private hospital (IMO, Barcelona, Spain).
Heliyon
January 2025
Department of Cataract, Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan, Shanxi, 030001, China.
Purpose: Using a fully automated multitask deep learning method, which enabled simultaneous segmentation and quantification of all major anterior segment structures with swept-source optical coherence tomography (SS-OCT), we aimed to investigate the three-dimensional (3D) alterations in iris morphology before and after implantable collamer lens (ICL) surgery.
Methods: All enrolled patients underwent anterior segment SS-OCT (ANTERION) within one week before and after ICL surgery. A multitask network automatically performed iris SS-OCT image segmentation and quantitative measurements of 3D iris morphology (iris thickness and volume of the inner 1-mm annular area and the outer 1-2-mm annular area, iris curvature [I-Curve], and iris smooth index [SI]).
Ultrasonics
January 2025
Acoustic and Application Group, Federal University of Alagoas, Campus Arapiraca, Brazil. Electronic address:
3D printing technology, also known as Additive Manufacturing (AM), has revolutionized object prototyping, offering a simple, cost-effective, and efficient approach to creating structures with diverse spatial features. However, the mechanical properties of 3D-printed structures are highly dependent on the material type and manufacturing technique employed. In this study, ultrasonic testing methods were used to comprehensively characterize standard samples produced using two popular printing techniques: material extrusion and vat photopolymerization.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!