The accurate duplicate cast obtained from a single impression reduces the profession clinical time, patient inconvenience, and extra material cost. The stainless steel working cast model assembly consisting of two abutments and one pontic area was fabricated. Two sets of six each custom aluminum trays were fabricated, with five mm spacer and two mm spacer. The impression methods evaluated during the study were additional silicone putty reline (two steps), heavy-light body (one step), monophase (one step), and polyether (one step). Type IV gypsum casts were poured at the interval of one hour, 12 hours, 24 hours, and 48 hours. The resultant cast was measured with traveling microscope for the comparative dimensional accuracy. The data obtained were subjected to Analysis of Variance test at significance level <0.05. The die obtained from two-step putty reline impression techniques had the percentage of variation for the height -0.36 to -0.97%, while diameter was increased by 0.40-0.90%. The values for one-step heavy-light body impression dies, additional silicone monophase impressions, and polyether were -0.73 to -1.21%, -1.34%, and -1.46% for the height and 0.50-0.80%, 1.20%, and -1.30% for the width, respectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5206852PMC
http://dx.doi.org/10.1155/2016/7414737DOI Listing

Publication Analysis

Top Keywords

impression methods
8
hours hours
8
accuracy multiple
4
multiple pour
4
cast
4
pour cast
4
cast elastomer
4
elastomer impression
4
methods accurate
4
accurate duplicate
4

Similar Publications

Autism Spectrum Disorder Traits Predict Interoceptive Deficits and Eating Disorder Symptomatology in Children and Adolescents with Anorexia Nervosa-A Cross-Sectional Analysis: Italian Preliminary Data.

Pediatr Rep

December 2024

IRCCS Istituto delle Scienze Neurologiche di Bologna, UOC Neuropsichiatria dell'Età Pediatrica, Centro Regionale per i Disturbi della Nutrizione e dell'Alimentazione in età evolutiva, 40139 Bologna, Italy.

Background: Anorexia Nervosa (AN) is a severe Feeding and Eating Disorder (FED) that is more prevalent in females, often manifesting during adolescence. Recent research highlights an elevated presence of comorbid Autism Spectrum Disorder (ASD) traits among individuals with AN, with specific expressions in females accounting for sensorial and interoceptive experiences. This study retrospectively explores the association between ASD traits, eating symptomatology, and interoceptive deficits in Italian female adolescents with AN.

View Article and Find Full Text PDF

Objective: This study aimed to assess and compare the internal fit of custom-made posts and cores fabricated using digital impressions (DI) and conventional vinyl polysiloxane (VPS) impressions in restorative dentistry.

Materials And Methods: A typodont tooth model, simulating the anatomy of the root canal of a central incisor, was utilized for the study. Two groups were formed, Group A and Group B, and each group provided a total of 18 impressions of two types: DIs and VPS impressions.

View Article and Find Full Text PDF

Near-Infrared Spectroscopy Allows for Monitoring of Bone Fracture Healing via Changes in Oxygenation.

J Funct Biomater

December 2024

Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, 66421 Homburg, Germany.

Bone fractures are associated with hypoxia, but no longitudinal studies of perfusion measurements in human patients have been reported despite the clinical and research potential. In this longitudinal observational cohort study, the near-infrared spectroscopy (NIRS) device PortaMon was used to assess oxy-(OHb), deoxy-(HHb) and total (tHb) haemoglobin, as well as the differences between OHb and HHb (Hb) and the tissue saturation index (TSI) at three different depths in the fracture gap. Linear mixed effect models were fitted to analyse time effects.

View Article and Find Full Text PDF

Occlusion plays a crucial role in the long-term success and functionality of dental restorations. The purpose of this study was to investigate the changes in occlusal contacts upon the cementation of zirconia crowns with different cement spacer settings in computer-aided design and computer-aided manufacturing (CAD-CAM) software (3Shape Dental System version 2.102.

View Article and Find Full Text PDF

The growing demand for detection and sensing in the biomedical field is placing higher demands on technology. In clinical testing, it is expected to be able to realize both rapid large-field imaging and analysis of single particles (or single molecules or single cells), and it is expected to be able to grasp both the unique individuality of single particles in time and space during the complex reaction process, as well as the regular correlation between single particles in the same population distribution. Supported and promoted by the theory of localized surface plasmon resonance (LSPR), dark-field microscopy, as a single-particle optical imaging technique with a very high signal-to-noise ratio, provides a powerful new means to address the above clinical detection needs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!