Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Home telemonitoring (HTM) of chronic heart failure (HF) promises to improve care by timely indications when a patient's condition is worsening. Simple rules of sudden weight change have been demonstrated to generate many alerts with poor sensitivity. Trend alert algorithms and bio-impedance (a more sensitive marker of fluid change), should produce fewer false alerts and reduce workload. However, comparisons between such approaches on the decisions made and the time spent reviewing alerts has not been studied.
Methods: Using HTM data from an observational trial of 91 HF patients, a simulated telemonitoring station was created and used to present virtual caseloads to clinicians experienced with HF HTM systems. Clinicians were randomised to either a simple (i.e. an increase of 2 kg in the past 3 days) or advanced alert method (either a moving average weight algorithm or bio-impedance cumulative sum algorithm).
Results: In total 16 clinicians reviewed the caseloads, 8 randomised to a simple alert method and 8 to the advanced alert methods. Total time to review the caseloads was lower in the advanced arms than the simple arm (80 ± 42 vs. 149 ± 82 min) but agreements on actions between clinicians were low (Fleiss kappa 0.33 and 0.31) and despite having high sensitivity many alerts in the bio-impedance arm were not considered to need further action.
Conclusion: Advanced alerting algorithms with higher specificity are likely to reduce the time spent by clinicians and increase the percentage of time spent on changes rated as most meaningful. Work is needed to present bio-impedance alerts in a manner which is intuitive for clinicians.