Beyond Bernoulli: Improving the Accuracy and Precision of Noninvasive Estimation of Peak Pressure Drops.

Circ Cardiovasc Imaging

From the King's College London, Division of Biomedical Engineering and Imaging Sciences, St. Thomas' Hospital, The Rayne Institute, United Kingdom (F.D., N.P.S., D.A.N., P.L.); Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, United Kingdom (S.M., M.M.B., S.N.); University of Auckland, New Zealand (N.P.S.); and Department of Non Invasive Cardiology, King's College Hospital, London, United Kingdom (M.J.M.).

Published: January 2017

Background: Transvalvular peak pressure drops are routinely assessed noninvasively by echocardiography using the Bernoulli principle. However, the Bernoulli principle relies on several approximations that may not be appropriate, including that the majority of the pressure drop is because of the spatial acceleration of the blood flow, and the ejection jet is a single streamline (single peak velocity value).

Methods And Results: We assessed the accuracy of the Bernoulli principle to estimate the peak pressure drop at the aortic valve using 3-dimensional cardiovascular magnetic resonance flow data in 32 subjects. Reference pressure drops were computed from the flow field, accounting for the principles of physics (ie, the Navier-Stokes equations). Analysis of the pressure components confirmed that the spatial acceleration of the blood jet through the valve is most significant (accounting for 99% of the total drop in stenotic subjects). However, the Bernoulli formulation demonstrated a consistent overestimation of the transvalvular pressure (average of 54%, range 5%-136%) resulting from the use of a single peak velocity value, which neglects the velocity distribution across the aortic valve plane. This assumption was a source of uncontrolled variability.

Conclusions: The application of the Bernoulli formulation results in a clinically significant overestimation of peak pressure drops because of approximation of blood flow as a single streamline. A corrected formulation that accounts for the cross-sectional profile of the blood flow is proposed and adapted to both cardiovascular magnetic resonance and echocardiographic data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5265685PMC
http://dx.doi.org/10.1161/CIRCIMAGING.116.005207DOI Listing

Publication Analysis

Top Keywords

peak pressure
16
pressure drops
16
bernoulli principle
12
blood flow
12
pressure
8
pressure drop
8
spatial acceleration
8
acceleration blood
8
single streamline
8
single peak
8

Similar Publications

Correlation between night sweats and season fluctuation in China.

Front Public Health

January 2025

Shandong Academy of Chinese Medicine, Jinan, China.

Background: Night sweats are a condition in which an individual sweats excessively during sleep without awareness, and stops when they wake up. Prolonged episodes of night sweats might result in the depletion of trace elements and nutrients, affecting the growth and development of children.

Purpose: To investigate the relationship between sweat nights and season.

View Article and Find Full Text PDF

Bone is one of the hardest tissues in the human body, but it can undergo microcracks under long-term and periodic mechanical loads. The Newton iterative method was used to calculate the steady state, and the effects of different inlet and outlet pressures, trabecular gap width and height, and microcrack's depth and width on the fluid shear stress (FSS) were studied, and the gradient of FSS inside the microcrack was analyzed. The results show that the pressure difference and trabecular gap heigh are positively correlated with the FSS (the linear correlation coefficients were 0.

View Article and Find Full Text PDF

Our previous study revealed the benefits of chronic melatonin intake on dynamic postural imbalance and poor walking capacity induced by multiple sclerosis but its impact on muscle weakness and poor manual dexterity related to this disease has not yet been explored. The objective of the current study was to investigate the effectiveness of 12-week melatonin supplementation on motor skills (i.e.

View Article and Find Full Text PDF

With increasing mining depth, the coal pillars of a coal mine will be in a stressful environment characterized by high gas pressures and unidirectional loading. To investigate the damage evolution characteristics and energy evolution mechanism of coal pillars loaded in a gas pressure environment, a uniaxial compression test was performed on a coal body under different gas pressures using a load testing apparatus for gas-containing coal rocks. The obtained results showed that the mechanical properties of the coal body varied with the gas pressure.

View Article and Find Full Text PDF

Aims: The Tpeak-Tend interval on electrocardiogram may be a predictor of worse outcomes in Takotsubo syndrome (TTS), but the mechanisms have not been fully determined. This study aimed to investigate the relationships between the corrected Tpeak-Tend (cTp-e) interval and coronary microvascular-dysfunction (CMD) assessed by the angiography-derived index of microvascular resistance (Angio-IMR) and the in-hospital prognosis in patients with TTS.

Methods And Results: We retrospectively evaluated 111 consecutive patients admitted for TTS who underwent coronary angiography at Kindai University Hospital from October 2009 to July 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!