Background: Tuberosity repair in shoulder fracture prosthesis implantation still remains a challenge often leading to poor functional outcomes, despite a variety of materials and suggested suture patterns. We aimed to evaluate, which forces currently used suture and cerclage materials withstand and to assess whether they are useful with regard to stability of reconstruction of tuberosities and which failure modes they display.
Material And Methods: Using sheep infraspinatus tendons with attached tuberosities three different suture materials (suture 1: Ethibond size 2; suture 2: Orthocord size 2; suture 3: Fiberwire size 5) and a 0.8mm titanium cerclage wire were investigated. For each suture material as well as the cerclage wire 6 tests were carried out. A material testing machine was used to perform cyclic loading tests (20mm/min, F=50N, F=100N, respectively after 50 cycles: F+50N until failure). Outcome measures and thus comparison criteria were the maximum holding force, number of cycles reached, total elongation of the system (tendon and suture) and qualitative appraisal and documentation of the mechanism of failure.
Results: Overall average maximum forces between the fixation materials differed significantly (P=0.003), especially suture 3 (braided polyethylene coating, non-resorbable polyfile UHMW core) displayed superior results in comparison to the cerclage wire (P=0.016). Although, primary elongation of the cerclage technique was significantly lower compared to the suture materials (P=0.002). All tests showed a high initial lengthening and caused incision-like defects in the bone or tendon and led to failure and huge displacement of the tuberosities.
Discussion: Currently used suture and cerclage materials have a limited usefulness for refixation of tuberosities due to an increased risk of obstruction for bony consolidation.
Level Of Evidence: Basic science, Biomechanics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2016.12.001 | DOI Listing |
JPRAS Open
March 2025
Plastic & Reconstructive Surgery Department, Prince Sultan Military Medical City, Riyadh, Saudi Arabia.
Background: Metacarpal shaft fractures account for 30 % of all hand fractures, and long oblique and spiral shaft fractures represent a significant quantity. Closed or open reduction and internal fixation is generally indicated for unstable fractures, rotational malalignment or significant metacarpal shortening. Various techniques can achieve appropriate fixation, though no single technique has been proven to be superior across all cases.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Ankara Etlik City Hospital, Ankara, Turkey.
Background: Cementless hip hemiarthroplasty is one of the options for the treatment of osteoporotic femoral neck fractures. Intraoperative periprosthetic femoral calcar fractures sometimes occur during the surgery, and the use of cerclage wiring to maintain the position and stability of the femoral stem and prevent the progression of the fracture. This study examines the outcomes of cerclage wiring to treat intraoperative periprosthetic calcar fractures in cementless hip hemiarthroplasty in osteoporotic femoral neck fractures.
View Article and Find Full Text PDFOrthop Surg
January 2025
Department of Orthopedics Surgery, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu Province, China.
Objective: Inferior pole patellar fractures (IPPFs) pose a significant challenge due to their complex fracture patterns and high risk of complications associated with current treatment methods. This study aims to (1) characterize the fracture patterns of IPPFs using fracture mapping and (2) compare the biomechanical stability and clinical outcomes of treatment with anchor suture with patellar cerclage versus Kirschner-wire tension band combined with patellar cerclage.
Methods: (1) A retrospective analysis was conducted on 61 patients with IPPF.
BMC Musculoskelet Disord
December 2024
The Fourth Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang, China.
Background: Patellar fractures present challenges in treatment, with traditional methods often leading to complications such as loss of reduction and implant failure. This study aimed to compare a novel suture fixation technique with the traditional tension band method using finite element analysis.
Methods: CT images of a healthy 35-year-old male were used to construct 3D patellar models.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!