Objective: To evaluate the impact of functional bladder capacity (FBC) on clinical outcomes after a staged neuromodulation procedure.
Materials And Methods: Adults in our prospective neuromodulation database were evaluated. Data were collected from medical records, voiding diaries (FBC defined as average volume per void), Interstitial Cystitis Symptom Index-Problem Index, Overactive Bladder Questionnaire, and Global Response Assessment over 3 months. Descriptive statistics, Pearson's chi-square tests, Wilcoxon rank sum tests, logistic regression, repeated measures analyses, and Spearman correlation coefficients were performed.
Results: Of the 216 patients (mean age 59 years; 84% female), most had urinary urgency and frequency with or without urge incontinence (71%), a sacral lead placement (82%), and implantable pulse generator (IPG) implantation (92%). Baseline FBC was similar between implanted and not implanted patients (P = .17); however implanted patients had a median 19 mL increase in FBC after lead placement compared to a 2.7 mL decrease in explanted patients (P = .0014). There was a strong association between percent change in FBC after lead placement and IPG implantation (P = .021; C-statistic 0.68), but baseline FBC (mL) was not associated. Baseline FBC (mL), or percent change in FBC after lead placement, was not related to symptom improvement. When grouped by baseline FBC < 150 mL and FBC ≥ 150 mL, FBC only improved significantly in the <150 group but both demonstrated significant improvements in symptoms.
Conclusion: FBC improvements were associated with IPG implantation but not other symptom measures. Patients with low FBC (baseline FBC < 150) also achieved significant improvements in symptoms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.urology.2017.01.008 | DOI Listing |
Animals (Basel)
December 2024
Department of Veterinary Medicine, Kangwon National University, Chuncheon-si 24341, Gangwon-do, Republic of Korea.
A 3D-printed guide is an effective method for accurately placing pedicle screws in dog vertebrae. While a conventional drill guide allows precise pilot hole formation, it can lead to potential screw wobbling during insertion. In this study, we applied a technique that assists with both drilling and screw insertion, and we compared the accuracy of screw placement using this approach with that achieved by the conventional drill guide.
View Article and Find Full Text PDFDrug Metab Pharmacokinet
November 2024
Laboratory of Molecular Toxicology, School of Pharmaceutical Sciences, University of Shizuoka, 52-1 Yada, Suruga-ku, Shizuoka, 422-8526, Japan.
The previously reported Template system for the prediction of human CYP2B6-mediated reactions (Drug Metab Pharmacokinet 26 309-330, 2011) has been refined with the introduction of ideas of allowable width, Trigger-residue and the residue-initiated movement of ligands in the active site. The refined system also includes ideas of bi-molecule binding on Template. With the use of these ideas in common with other Template systems for human CYP1A1, CYP1A2, CYP2C8, CYP2C9, CYP2C18, CYP2C19, CYP2E1, and CYP3A4, 360 reactions of 261 distinct chemicals reported as CYP2B6 ligands were examined in the refined system.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Service de rythmologie cardiaque, Hôpital Cardiologique Louis Pradel, Hospices Civils de Lyon, Lyon, France.
Background: Temporary transvenous pacing (TTP) is a common procedure, predominantly performed in the catheterization laboratory (cath lab) because of presumed lower complication rate. This study aims to evaluate the efficacy and safety of TTP placement in the ICU compared to TTP placement in the cath lab.
Methods: This retrospective, real-life study included all patients requiring TTP in a tertiary care ICU between 2019 and 2022.
Front Public Health
January 2025
Department of Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Philadelphia, PA, United States.
Background: Mass vaccination is a cornerstone of public health emergency preparedness and response. However, injudicious placement of vaccination sites can lead to the formation of long waiting lines or , which discourages individuals from waiting to be vaccinated and may thus jeopardize the achievement of public health targets. Queueing theory offers a framework for modeling queue formation at vaccination sites and its effect on vaccine uptake.
View Article and Find Full Text PDFJBJS Essent Surg Tech
January 2025
The Ohio State University College of Medicine, Columbus, Ohio.
Background: An all-inside endoscopic flexor hallucis longus (FHL) tendon transfer is indicated for the treatment of chronic, full-thickness Achilles tendon defects. The aim of this procedure is to restore function of the gastrocnemius-soleus complex while avoiding the wound complications associated with open procedures.
Description: This procedure can be performed through 2 endoscopic portals, a posteromedial portal (the working portal) and a posterolateral portal (the visualization portal).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!