Statement Of Problem: Although many systems are used to polish zirconia, a comparison of the performance of zirconia and feldspathic porcelain polishing systems is lacking.
Purpose: The purpose of this in vitro study was to compare the effects of 3 polishing systems on surface roughness, zirconia phase transformation, and durability of the polishing systems when applied to zirconia and feldspathic porcelain.
Material And Methods: Three polishing systems were evaluated: Z1, a zirconia polishing system; Z2, a zirconia polishing system, and F1, a feldspathic porcelain polishing system. Three ceramic systems were evaluated: PR and ZM zirconia specimens (diameter 15 mm, height 2 mm; 23 specimens each) and CB feldspathic porcelain specimens of the same size (15 specimens). A rough surface was created on the 3 types of specimens (15 specimens each) to model an occlusal adjustment under the same conditions. Polishing was carried out with the 3 polishing systems for 2 minutes each. Surface roughness was measured with a 3-dimensional (3D) optical profiler. The surface was also observed with a scanning electron microscopy. X-ray diffraction analysis was performed for 8 PR or ZM zirconia specimens polished by using the Z1 and Z2 systems for 8 minutes to evaluate the phase transformation of zirconia before, during, and after polishing. These specimens were compared and analyzed for phase transformation that might have occurred during the polishing of the specimens. After finishing the surface roughness experiment and the phase transformation experiment, the volumes of the polishers were measured with a 3D volume scanner and compared with those before the experiments to evaluate the durability of the polishing system. A statistical analysis of all data was performed using 2-way ANOVA and the Tukey honest significant difference test (α=.05).
Results: The 2 zirconia polishing systems (Z1, Z2) created a significantly (P<.001) smoother surface, regardless of the type of specimens used for polishing, than the feldspathic porcelain polishing system (F1). When polishing treatment was carried out on zirconia specimens for 8 minutes, the maximum percentages of monoclinic phase increased by 0.03% in the Z1 system and by 0.09% in the Z2 system. The volume change for the durability evaluation of the polishing system was 13.35 and 29.37% in the Z1 system, 2.05 and 5.92% in the Z2 system, and 3.60 and 4.95% in the F1 system, respectively.
Conclusions: Zirconia polishing systems created a smoother surface on zirconia than the feldspathic porcelain polishing system. No significant changes in the phase transformation of zirconia were found before and after polishing. Each polishing system showed different levels of wear resistance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2016.10.005 | DOI Listing |
J Environ Sci Health A Tox Hazard Subst Environ Eng
January 2025
Crop Science Discipline, University of KwaZulu-Natal, Pietermaritzburg, South Africa.
To meet wastewater treatment quality standards for reuse, integrating advanced oxidation processes (AOPs) with Decentralized Wastewater Treatment Systems (DEWATS) is promising. This study aimed to optimize AOPs (ozonolysis, UV photolysis, TiO photocatalysis) for polishing anaerobic filter (AF) effluent from DEWATS, as an alternative to constructed wetlands. Metrics included pathogen reduction efficiency, post-disinfection regrowth, and effects on physical parameters (pH, EC, turbidity), organic matter (soluble COD, BOD, DOC, humic), and nutrient concentration (ammonium, nitrates, ortho-P).
View Article and Find Full Text PDFPolymers (Basel)
January 2025
Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, China.
The highly selective and sensitive determination of pesticide residues in food is critical for human health protection. Herein, the specific selectivity of molecularly imprinted polymers (MIPs) was proposed to construct an electrochemical sensor for the detection of carbendazim (CBD), one of the famous broad-spectrum fungicides, by combining with the synergistic effect of bioelectrocatalysis and nanocomposites. Gold nanoparticle-reduced graphene oxide (AuNP-rGO) composites were electrodeposited on a polished glassy carbon electrode (GCE).
View Article and Find Full Text PDFNanomaterials (Basel)
January 2025
School of Artificial Intelligence, Optics and Electronics (iOPEN), Northwestern Polytechnical University, Xi'an 710072, China.
This study presents a novel reflective fiber Fabry-Perot (F-P) salinity sensor. The sensor employs a femtosecond laser to fabricate an open liquid cavity, facilitating the unobstructed ingress and egress of the liquid, thereby enabling the direct involvement of the liquid in light transmission. Variations in the refractive index of the liquid induce corresponding changes in the effective refractive index of the optical path, which subsequently influences the output spectrum.
View Article and Find Full Text PDFJ Conserv Dent Endod
November 2024
Department of Conservative Dentistry and Endodontics, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeth Deemed to be University, Vadodara, Gujarat, India.
Aim: The aim of the study was to compare and evaluate proximal contact tightness and contours using two newer contact-forming systems in Class II composite restorations.
Materials And Methods: After institutional ethical approval and Clinical Trials Registry-India registration, patients were chosen according to the inclusion-exclusion criteria with informed consent. A total of 60 patients were randomly assigned to two groups.
Oper Orthop Traumatol
January 2025
AOFE Clinics Oosterbeek, Oosterbeek, The Netherlands.
Objective: Transcutaneous osseointegration prosthetic systems (TOPS) offer a stable skeletal attachment for artificial limbs post-extremity amputation, serving as an alternative to socket attachment. Press-fit osseointegration implants (OI) utilized in TOPS consistently enhance quality of life and mobility for amputees, particularly those experiencing socket-related issues. Despite notable benefits, late complications such as infection and implant loosening pose challenges unique to TOPS due to their percutaneous nature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!