Background: This study was conducted to determine the association between aortic pulse pressure (APP) and left ventricular (LV) filling pressure in the elderly of both genders.

Methods: A total of 211 stable elderly subjects (age ≥65 years, mean age 72.1 ± 5.2 years, 53.6% women) who underwent invasive coronary angiography (ICA) for the evaluation of coronary artery disease (CAD) were prospectively investigated. APP was measured in the ascending aorta using a pigtail catheter immediately before ICA. E/e', reflecting LV filling pressure, was assessed by transthoracic echocardiography.

Results: There were positive linear correlations between APP and E/e' in both genders, but the correlation power was stronger in women than in men (r = 0.402, P <.001 vs r = 0.208, P = .040). The significance of this association between APP and E/e' remained after controlling for potential confounders in multiple linear regression analysis in women (β = 0.359, P <.001), but not in men (r = 0.139, P = .108).

Conclusions: Invasively measured APP is independently associated with E/e' in elderly women, but not in elderly men undergoing ICA. Aortic stiffness may be a potential mechanism for more prevalent LV diastolic dysfunction and heart failure with preserved ejection fraction in elderly women.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cardfail.2017.01.001DOI Listing

Publication Analysis

Top Keywords

filling pressure
12
association aortic
8
aortic pulse
8
pulse pressure
8
left ventricular
8
ventricular filling
8
pressure elderly
8
pressure
5
gender difference
4
difference association
4

Similar Publications

Introduction: Preeclampsia (PE) is thought to be the consequence of impaired placental perfusion leading to placental hypoxia. While it has been demonstrated that PE may be a consequence of maternal cardiovascular maladaptation, the exact role of maternal cardiac function remains to be determined. This study sought to assess cardiac characteristics in pregnant women diagnosed with PE and to determine the possible relationship between PE, maternal cardiac changes/function, and NT-proBNP levels.

View Article and Find Full Text PDF

Leakage analysis and leakage monitoring system design for LNG tanker filling process.

Sci Rep

December 2024

PetroChina Kunlun Gas Co., Ltd. Sichuan Branch, Chengdu Sichua, China.

During the filling process of LNG tank trucks, due to the long-term operation of filling equipment in low temperature and high-pressure conditions, the sealing parts in the equipment are prone to failure, leading to leaks. The reasons for the leakage of LNG filling equipment were analyzed, and the diffusion of LNG after different equivalent leakage hole diameters and different wind speeds were numerically analyzed. A gas leak monitoring system suitable for LNG filling stations was established based on TDLAS technology.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how gut microbial metabolites (GMM), specifically phenylacetylglutamine (PAGln), are linked to cardiovascular diseases (CVD) in people with alcohol use disorder.
  • In experiments with mice, researchers found that chronic alcohol consumption led to changes in gut microbes and increased PAGln levels, which were associated with cardiovascular issues.
  • PAGln was shown to cause heart and blood vessel problems independent of alcohol, indicating that it plays a significant role in the development of CVD related to alcohol consumption.
View Article and Find Full Text PDF

Introduction: Detrusor contractions can be classified as either volitional or involuntary. The latter are a hallmark of urge urinary incontinence. Understanding differences in neuroactivation associated with both types of contractions can help elucidate pathophysiology and therapeutic targets.

View Article and Find Full Text PDF

This study investigates the use of multi-layered porous media (MLPM) to enhance thermal energy transfer within a counterflow double-pipe heat exchanger (DPHE). We conducted computational fluid dynamics (CFD) simulations on DPHEs featuring five distinct MLPM configurations, analyzed under both fully filled and partially filled conditions, alongside a conventional DPHE. The impact of various parameters such as porous layer arrangements, thickness, and flow Reynolds numbers on pressure drop, logarithmic mean temperature difference (LMTD), and performance evaluation criterion (PEC) was assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!