This study investigated reliability of freehand three-dimensional ultrasound (3DUS) measurement of in vivo human Achilles tendon (AT) moment arm. Sixteen healthy adults were scanned on 2 separate occasions by a single investigator. 3DUS scans were performed over the free AT, medial malleolus, and lateral malleolus with the ankle passively positioned in maximal dorsiflexion, mid dorsiflexion, neutral, mid plantar flexion and maximal plantar flexion. 3D reconstructions of the AT, medial malleolus, and lateral malleolus were created from manual segmentation of the ultrasound images and used to geometrically determine the AT moment arm using both a straight (straight AT) and curved (curved AT) tendon line-of-action. Both methods were reliable within- and between-session (intra-class correlation coefficients > 0.92; coefficient of variation < 2.5 %) and revealed that AT moment arm increased by ∼ 7 mm from maximal dorsiflexion (∼ 41mm) to maximal plantar flexion (∼ 48 mm). Failing to account for tendon curvature led to a small overestimation (< 2 mm) of AT moment arm that was most pronounced in ankle plantar flexion, but was less than the minimal detectable change of the method and could be disregarded.

Download full-text PDF

Source
http://dx.doi.org/10.1123/jab.2016-0261DOI Listing

Publication Analysis

Top Keywords

moment arm
12
achilles tendon
8
tendon moment
8
freehand three-dimensional
8
three-dimensional ultrasound
8
medial malleolus
8
malleolus lateral
8
lateral malleolus
8
plantar flexion
8
reliability achilles
4

Similar Publications

Background: Researchers have encountered challenges in recruiting unpaid caregivers of people living with Alzheimer disease and related dementias for intervention studies. However, little is known about the reasons for nonparticipation in in-home smart health interventions in community-based settings.

Objective: This study aimed to (1) assess recruitment rates in a smart health technology intervention for caregivers of people living with Alzheimer disease and related dementias and reasons for nonparticipation among them and (2) discuss lessons learned from recruitment challenges and strategies to improve recruitment.

View Article and Find Full Text PDF

Background: Hallux valgus (HV) is a complex, multiplanar deformity. In this study, we examined the interrelationships between various components of this deformity using weightbearing computed tomography (WBCT). We hypothesized that the severity of traditional axial plane deformities would correlate with malpositioning of the metatarsosesamoid complex, first-ray coronal rotational deformity, and malalignment of the hindfoot and midfoot.

View Article and Find Full Text PDF

Correlation coefficients play a pivotal role in quantifying linear relationships between random variables. Yet, their application to time series data is very challenging due to temporal dependencies. This paper introduces a novel approach to estimate the statistical significance of correlation coefficients in time series data, addressing the limitations of traditional methods based on the concept of effective degrees of freedom (or effective sample size, ESS).

View Article and Find Full Text PDF

Background: Personalized approaches to behavior change to improve mental and physical health outcomes are needed. Reducing the intensity, duration, and frequency of stress responses is a mechanism for interventions to improve health behaviors. We developed an ambulatory, dynamic stress measurement approach that can identify personalized stress responses in the moments and contexts in which they occur; we propose that intervening in these stress responses as they arise (ie, just in time; JIT) will result in positive impacts on health behaviors.

View Article and Find Full Text PDF

Diabetes presents a significant challenge to healthcare due to the short- and long-term complications associated with poor blood sugar control. Computer simulation platforms have emerged as promising tools for advancing diabetes therapy by simulating patient responses to treatments in a virtual environment. The University of Virginia Virtual Lab (UVLab) is a new simulation platform engineered to mimic the metabolic behavior of individuals with type 2 diabetes (T2D) using a mathematical model of glucose homeostasis in T2D and a large population of 6062 virtual subjects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!