To investigate the effect of dose calculation grid on calculated dose-volumetric parameters for eye lenses and optic pathways. A total of 30 patients treated using the volumetric modulated arc therapy (VMAT) technique, were retrospectively selected. For each patient, dose distributions were calculated with calculation grids ranging from 1 to 5 mm at 1 mm intervals. Identical structures were used for VMAT planning. The changes in dose-volumetric parameters according to the size of the calculation grid were investigated. Compared to dose calculation with 1 mm grid, the maximum doses to the eye lens with calculation grids of 2, 3, 4 and 5 mm increased by 0.2 ± 0.2 Gy, 0.5 ± 0.5 Gy, 0.9 ± 0.8 Gy and 1.7 ± 1.5 Gy on average, respectively. The Spearman's correlation coefficient between dose gradients near structures vs. the differences between the calculated doses with 1 mm grid and those with 5 mm grid, were 0.380 (p < 0.001). For the accurate calculation of dose distributions, as well as efficiency, using a grid size of 2 mm appears to be the most appropriate choice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s13246-016-0517-z | DOI Listing |
Int J Endocrinol
January 2025
Nephrology Department, Jiangxi Provincial Key Research Laboratory of Traditional Chinese Medicine, Key Research Laboratory of Chronic Renal Failure, Affiliated Hospital of Jiangxi University of Traditional Chinese Medicine, Nanchang, Jiangxi 330006, China.
This study aimed to investigate the potential mechanisms of puerarin in alleviating diabetic nephropathy (DKD) in mice. The DKD model was induced by multiple low-dose injections of streptozotocin (STZ) and a high-sugar and high-fat diet in male C57BL/6J mice. After confirming the onset of DKD, mice were given irbesartan, distilled water, or different concentrations of puerarin (40 and 80 mg/kg/d) by gavage for 8 weeks.
View Article and Find Full Text PDFFront Med (Lausanne)
January 2025
Department of Cardiology, Lishui Central Hospital and the Fifth Affiliated Hospital of Wenzhou Medical University, Lishui, China.
Background: The difference between the estimated glomerular filtration rate (eGFR) calculated from cystatin C and creatinine (eGFRdiff) serves as a biomarker of kidney function impairment. However, the role of eGFRdiff in cardiovascular-kidney-metabolic (CKM) health and its impact on mortality in CKM syndrome patients has not yet been studied.
Methods: This study included 3,622 participants from the National Health and Nutrition Examination Survey (NHANES) conducted between 1999 and 2004.
The food enzyme triacylglycerol lipase (triacylglycerol acylhydrolase, EC 3.1.1.
View Article and Find Full Text PDFThe food enzyme glucose oxidase (β-d-glucose: oxygen 1-oxidoreductase, EC 1.1.3.
View Article and Find Full Text PDFPhys Eng Sci Med
January 2025
Department of Physics and Radiation Safety, Nepean Hospital, Penrith, New South Wales, Australia.
The radiation exposure to bystanders from nuclear medicine patients is a common concern raised in nuclear medicine departments. The GATE (Geant4 Application for Tomographic Emission) Monte Carlo radiation transport application was used to estimate the dose to a bystander. Two voxelised phantoms were utilised in a GATE Monte Carlo simulation as the radiation source and target.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!