Radiolabeling of the prostate-specific membrane antigen (PSMA) inhibitor Glu-NH-CO-NH-Lys(Ahx) using the Ga chelator HBED-CC (PSMA) allows imaging of prostate cancer lesions because of high expression of PSMA in prostate carcinoma cells and in bone metastases and lymph nodes related to the disease. The aim of this work was to optimize labeling of Ga-PSMA using the efficient cation-exchange postprocessing of Ga as well as the development of a thin-layer chromatography (TLC)-based quality control system. Labeling was optimized for online ethanol-postprocessed Ga eluate investigating various parameters, such as buffer molarity (0.1-1 M), temperature (25°C-90°C), tracer amount (0.11-0.74 nmol), and labeling time. In addition, purification of the crude product was tested. For radio-TLC quality control, various mobile phases were analyzed using silica gel 60 plates and the results were validated using high-performance liquid chromatography. The most superior mobile phases were also applied on instant thin-layer chromatography (ITLC) silica gel plates. Using optimized conditions, labeling yields of more than 95% were obtained within 10 min when ethanol-based postprocessing was applied using PSMA amounts as low as 0.1 nmol. A higher precursor concentration (0.7 nmol) further increased labeling and quantitative yields to more than 98% within 5 min. In clinical routine, patient batches (>200 applications) with radiochemical purity greater than 98% and specific activities of 326 ± 20 MBq/nmol are obtained reproducibly. When TLC quality control was performed on silica gel 60 plates, 4 mobile phases with suitable separation properties and complementary R values were identified. Two systems showed equivalent separation on ITLC silica gel plates, with ITLC analysis finished within 5 min, in contrast to 20 min for the TLC system. Labeling of PSMA was optimized for cation-exchange postprocessing methods, ensuring almost quantitative labeling and high nuclide purity of final Ga-PSMA, making subsequent purification steps unnecessary. The new radio-TLC method allows quality control in a short time using a fast, reliable, low-cost method with little equipment complexity. Using this approach, the synthesis is easily adopted by automated synthesis modules.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.116.177634DOI Listing

Publication Analysis

Top Keywords

quality control
20
silica gel
16
gel plates
16
mobile phases
12
labeling psma
8
cation-exchange postprocessing
8
thin-layer chromatography
8
system labeling
8
itlc silica
8
labeling
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!